Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
122,146
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0693 # 02 Y:2012 | 02 | 2012 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $15,776 | $43,000 | Not Implemented |
MA0693 # 03 Y:2012 | 03 | 2012 | REPAIR AND ELIMINATE STEAM LEAKS | $9,000 | $4,200 | Implemented |
MA0693 # 04 Y:2012 | 04 | 2012 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $6,573 | $27,000 | Not Implemented |
MA0693 # 05 Y:2012 | 05 | 2012 | INSTALL OCCUPANCY SENSORS | $1,572 | $4,200 | Implemented |
MA0693 # 06 Y:2012 | 06 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $486 | $200 | Not Implemented |
MA0693 # 07 Y:2012 | 07 | 2012 | INSULATE BARE EQUIPMENT | $373 | $600 | Not Implemented |
NC0448 # 01 Y:2012 | 01 | 2012 | ADOPT IN-HOUSE MATERIAL GENERATION | $42,880 | $75,000 | Not Implemented |
NC0448 # 02 Y:2012 | 02 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $19,522 | $100,000 | Not Implemented |
NC0448 # 03 Y:2012 | 03 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,746 | $5,600 | Implemented |
NC0448 # 04 Y:2012 | 04 | 2012 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,740 | $400 | Implemented |
NC0448 # 05 Y:2012 | 05 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $880 | $200 | Implemented |
DL0087 # 01 Y:2012 | 01 | 2012 | KEEP EQUIPMENT CLEAN | $378,860 | $370,000 | Implemented |
DL0087 # 02 Y:2012 | 02 | 2012 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $145,934 | $700 | Not Implemented |
DL0087 # 03 Y:2012 | 03 | 2012 | USE RADIANT HEATER FOR SPOT HEATING | $410,000 | $1,200,000 | Implemented |
DL0087 # 04 Y:2012 | 04 | 2012 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $20,000 | $78,000 | Implemented |
DL0087 # 05 Y:2012 | 05 | 2012 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $11,900 | $14,000 | Implemented |
DL0087 # 06 Y:2012 | 06 | 2012 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $17,900 | $54,500 | Not Implemented |
DL0087 # 07 Y:2012 | 07 | 2012 | SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS | $7,000 | $20,000 | Not Implemented |
DL0087 # 08 Y:2012 | 08 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,200 | $5,400 | Implemented |
DL0087 # 09 Y:2012 | 09 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $79,600 | $29,600 | Not Implemented |
DL0087 # 10 Y:2012 | 10 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $18,230 | $71,500 | Not Implemented |
DL0087 # 11 Y:2012 | 11 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $60,100 | $101,500 | Not Implemented |
MA0694 # 01 Y:2012 | 01 | 2012 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $12,023 | $500 | Implemented |
MA0694 # 02 Y:2012 | 02 | 2012 | REDUCE VENTILATION AIR | $7,473 | $0 | Not Implemented |
MA0694 # 03 Y:2012 | 03 | 2012 | MINIMIZE NON-ESSENTIAL MATERIAL IN HEAT TREATMENT PROCESS | $5,619 | $0 | Implemented |