Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,602
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0312 # 02 Y:1998 | 02 | 1998 | REPAIR AND ELIMINATE STEAM LEAKS | $24,560 | $5,000 | Implemented |
AM0312 # 03 Y:1998 | 03 | 1998 | METER WASTE WATER | $17,000 | $4,800 | Implemented |
AM0312 # 04 Y:1998 | 04 | 1998 | OPTIMIZE PLANT POWER FACTOR | $3,700 | $8,650 | Implemented |
AM0312 # 05 Y:1998 | 05 | 1998 | INSULATE BARE EQUIPMENT | $2,780 | $2,790 | Implemented |
AM0312 # 06 Y:1998 | 06 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,790 | $15 | Implemented |
AM0312 # 07 Y:1998 | 07 | 1998 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,710 | $1,250 | Implemented |
AM0312 # 08 Y:1998 | 08 | 1998 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $1,190 | $350 | Implemented |
AM0312 # 09 Y:1998 | 09 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $465 | $30 | Implemented |
AM0312 # 10 Y:1998 | 10 | 1998 | PAY UTILITY BILLS ON TIME | $310 | $0 | Implemented |
AM0311 # 01 Y:1998 | 01 | 1998 | REMOVE SLUDGE FROM TANKS ON A REGULAR BASIS | $116,000 | $900,000 | Not Implemented |
AM0311 # 02 Y:1998 | 02 | 1998 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $31,316 | $0 | Implemented |
AM0311 # 03 Y:1998 | 03 | 1998 | ELIMINATE PRACTICE OF MIXING WASTE STREAMS | $23,800 | $1,515 | Not Implemented |
AM0311 # 04 Y:1998 | 04 | 1998 | USE PHOTOCELL CONTROLS | $11,300 | $340 | Implemented |
AM0311 # 05 Y:1998 | 05 | 1998 | USE SYNTHETIC LUBRICANT | $2,785 | $0 | Not Implemented |
AM0311 # 06 Y:1998 | 06 | 1998 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $2,170 | $0 | Implemented |
AM0311 # 07 Y:1998 | 07 | 1998 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $1,620 | $1,010 | Implemented |
AM0311 # 08 Y:1998 | 08 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,500 | $2,100 | Implemented |
AM0311 # 09 Y:1998 | 09 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,400 | $0 | Not Implemented |
AM0311 # 10 Y:1998 | 10 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $1,105 | $1,205 | Implemented |
AM0311 # 11 Y:1998 | 11 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $290 | $93 | Not Implemented |
AM0311 # 12 Y:1998 | 12 | 1998 | INSTALL OCCUPANCY SENSORS | $250 | $485 | Not Implemented |
KG0100 # 01 Y:1997 | 01 | 1997 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $1,133 | $248 | n/a |
KG0100 # 02 Y:1997 | 02 | 1997 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $6,859 | $1,744 | n/a |
KG0100 # 03 Y:1997 | 03 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $4,554 | $0 | n/a |
KG0100 # 04 Y:1997 | 04 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $1,484 | $0 | n/a |