Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,417
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0091 # 02 Y:1990 | 02 | 1990 | OPTIMIZE PLANT POWER FACTOR | $19,523 | $21,750 | Not Implemented |
OR0091 # 03 Y:1990 | 03 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $9,377 | $26,425 | Not Implemented |
OR0091 # 04 Y:1990 | 04 | 1990 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,263 | $2,745 | Not Implemented |
OR0092 # 01 Y:1990 | 01 | 1990 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $5,335 | $0 | Implemented |
OR0092 # 02 Y:1990 | 02 | 1990 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,064 | $150 | Implemented |
OR0092 # 03 Y:1990 | 03 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $120,588 | $0 | Implemented |
OR0092 # 04 Y:1990 | 04 | 1990 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $773 | $839 | Implemented |
OR0092 # 05 Y:1990 | 05 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $19,870 | $35,000 | Implemented |
OR0092 # 06 Y:1990 | 06 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,711 | $4,175 | Not Implemented |
OR0092 # 07 Y:1990 | 07 | 1990 | OPTIMIZE PLANT POWER FACTOR | $1,008 | $2,625 | Not Implemented |
TN0412 # 01 Y:1990 | 01 | 1990 | USE MINIMUM STEAM OPERATING PRESSURE | $46,500 | $0 | Implemented |
TN0412 # 02 Y:1990 | 02 | 1990 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $11,598 | $10,600 | Not Implemented |
TN0412 # 03 Y:1990 | 03 | 1990 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $7,159 | $0 | Implemented |
TN0412 # 04 Y:1990 | 04 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,317 | $1,500 | Implemented |
TN0412 # 05 Y:1990 | 05 | 1990 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $8,740 | $2,460 | Not Implemented |
TN0412 # 06 Y:1990 | 06 | 1990 | IMPROVE LUBRICATION PRACTICES | $4,345 | $0 | Not Implemented |
TN0413 # 01 Y:1990 | 01 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $17,798 | $7,260 | Implemented |
TN0413 # 02 Y:1990 | 02 | 1990 | KEEP LAMPS AND REFLECTORS CLEAN | $5,149 | $12,840 | Implemented |
TN0413 # 03 Y:1990 | 03 | 1990 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $256 | $300 | Implemented |
TN0413 # 04 Y:1990 | 04 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $919 | $563 | Implemented |
TN0413 # 05 Y:1990 | 05 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $230 | $325 | Implemented |
UD0328 # 01 Y:1990 | 01 | 1990 | REDUCE VENTILATION AIR | $409 | $1,000 | Implemented |
UD0328 # 02 Y:1990 | 02 | 1990 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $3,201 | $3,000 | Not Implemented |
UD0328 # 03 Y:1990 | 03 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $2,019 | $0 | Implemented |
UD0328 # 04 Y:1990 | 04 | 1990 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $1,328 | $400 | Not Implemented |