ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0220 # 01 Y:2002 | 01 | 2002 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $97,351 | $42,000 | Not Implemented |
BD0220 # 02 Y:2002 | 02 | 2002 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $30,813 | $19,400 | Implemented |
BD0220 # 03 Y:2002 | 03 | 2002 | SUBSTITUTE HOT PROCESS FLUIDS FOR STEAM | $12,225 | $5,000 | Not Implemented |
BD0220 # 04 Y:2002 | 04 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,957 | $900 | Implemented |
BD0220 # 05 Y:2002 | 05 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,480 | $1,700 | Not Implemented |
BD0220 # 06 Y:2002 | 06 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,308 | $3,000 | Implemented |
BD0220 # 10 Y:2002 | 10 | 2002 | INSTALL TURBULATORS | $925 | $3,200 | Not Implemented |
BD0220 # 09 Y:2002 | 09 | 2002 | INSTALL OCCUPANCY SENSORS | $1,733 | $900 | Implemented |
BD0220 # 08 Y:2002 | 08 | 2002 | INSTALL AUTOMATIC STACK DAMPER | $1,938 | $2,500 | Not Implemented |
BD0220 # 07 Y:2002 | 07 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,161 | $0 | Implemented |
BD0219 # 01 Y:2002 | 01 | 2002 | USE RADIANT HEATER FOR SPOT HEATING | $12,344 | $22,000 | Implemented |
BD0219 # 02 Y:2002 | 02 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,195 | $17,710 | Implemented |
BD0219 # 03 Y:2002 | 03 | 2002 | USE SYNTHETIC LUBRICANT | $2,594 | $800 | Implemented |
BD0219 # 04 Y:2002 | 04 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,360 | $1,600 | Implemented |
BD0219 # 05 Y:2002 | 05 | 2002 | INSTALL OCCUPANCY SENSORS | $1,308 | $1,650 | Not Implemented |
BD0219 # 06 Y:2002 | 06 | 2002 | USE PHOTOCELL CONTROLS | $604 | $1,000 | Implemented |
BD0219 # 07 Y:2002 | 07 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $458 | $557 | Not Implemented |
BD0219 # 08 Y:2002 | 08 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $254 | $480 | Not Implemented |
BD0219 # 09 Y:2002 | 09 | 2002 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $1,725 | $5,000 | Not Implemented |
BD0219 # 10 Y:2002 | 10 | 2002 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $23,058 | $10,000 | Not Implemented |
BD0219 # 11 Y:2002 | 11 | 2002 | MINIMIZE WATER USAGE | $753 | $690 | Not Implemented |
UU0037 # 04 Y:2002 | 04 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,174 | $20 | Not Implemented |
UU0037 # 03 Y:2002 | 03 | 2002 | OPTIMIZE PLANT POWER FACTOR | $1,896 | $2,861 | Not Implemented |
UU0037 # 02 Y:2002 | 02 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $675 | $420 | Not Implemented |
UU0037 # 01 Y:2002 | 01 | 2002 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,120 | $0 | Not Implemented |