Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,333
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0377 # 03 Y:2000 | 03 | 2000 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $97,815 | $113,670 | Not Implemented |
OR0377 # 04 Y:2000 | 04 | 2000 | ELIMINATE PRACTICE OF MIXING WASTE STREAMS | $108,000 | $40,000 | Implemented |
OR0380 # 01 Y:2000 | 01 | 2000 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $89,400 | $280,000 | Not Implemented |
OR0380 # 02 Y:2000 | 02 | 2000 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $15,389 | $29,590 | Not Implemented |
OR0380 # 03 Y:2000 | 03 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $15,954 | $30,046 | Implemented |
OR0380 # 04 Y:2000 | 04 | 2000 | OPTIMIZE PLANT POWER FACTOR | $4,853 | $13,600 | Implemented |
OR0380 # 05 Y:2000 | 05 | 2000 | USE PHOTOCELL CONTROLS | $3,605 | $605 | Implemented |
OR0380 # 06 Y:2000 | 06 | 2000 | UPGRADE CONTROLS ON COMPRESSORS | $647 | $0 | Implemented |
OR0380 # 07 Y:2000 | 07 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,013 | $0 | Not Implemented |
OR0380 # 08 Y:2000 | 08 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,344 | $7,500 | Not Implemented |
WV0205 # 01 Y:2000 | 01 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,419 | $800 | Not Implemented |
WV0205 # 02 Y:2000 | 02 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,709 | $800 | Not Implemented |
WV0205 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $347 | $519 | Implemented |
WV0205 # 04 Y:2000 | 04 | 2000 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $7,568 | $3,000 | Implemented |
WV0205 # 05 Y:2000 | 05 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $394 | $50 | Implemented |
WV0205 # 06 Y:2000 | 06 | 2000 | INSTALL SPECTRAL REFLECTORS / DELAMP | $7,688 | $7,933 | Implemented |
WV0205 # 07 Y:2000 | 07 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,511 | $600 | Not Implemented |
WV0205 # 08 Y:2000 | 08 | 2000 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $6,109 | $1,500 | Not Implemented |
WV0205 # 09 Y:2000 | 09 | 2000 | USE OPTIMUM THICKNESS INSULATION | $171 | $375 | Implemented |
WV0205 # 10 Y:2000 | 10 | 2000 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $9,414 | $1,000 | Implemented |
WV0205 # 11 Y:2000 | 11 | 2000 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $480 | $100 | Implemented |
WV0205 # 12 Y:2000 | 12 | 2000 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $80 | $0 | Implemented |
WV0205 # 13 Y:2000 | 13 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $5,182 | $7,000 | Not Implemented |
WV0205 # 14 Y:2000 | 14 | 2000 | INSTALL EQUIPMENT TO MOVE PRODUCT | $77,688 | $750 | Not Implemented |
WV0205 # 15 Y:2000 | 15 | 2000 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $35,000 | $5,000 | Not Implemented |