Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,640
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0193 # 01 Y:2001 | 01 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $262 | $489 | Not Implemented |
MS0193 # 02 Y:2001 | 02 | 2001 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $4,853 | $0 | Implemented |
MS0193 # 03 Y:2001 | 03 | 2001 | DISCONNECT BALLASTS | $2,179 | $3,078 | Implemented |
MS0193 # 04 Y:2001 | 04 | 2001 | INSTALL TIMERS AND/OR THERMOSTATS | $963 | $408 | Not Implemented |
MS0193 # 05 Y:2001 | 05 | 2001 | INSTALL TIMERS AND/OR THERMOSTATS | $17,990 | $2,183 | Not Implemented |
MS0193 # 06 Y:2001 | 06 | 2001 | INSULATE BARE EQUIPMENT | $87 | $10 | Not Implemented |
NC0227 # 01 Y:2001 | 01 | 2001 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,391 | $250 | Not Implemented |
NC0227 # 02 Y:2001 | 02 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $15,815 | $30,000 | Not Implemented |
NC0227 # 03 Y:2001 | 03 | 2001 | INSTALL / REPAIR INSULATION ON STEAM LINES | $662 | $308 | Not Implemented |
NC0227 # 04 Y:2001 | 04 | 2001 | IMPROVE COMBUSTION CONTROL CAPABILITY | $89,586 | $60,000 | Not Implemented |
NC0227 # 05 Y:2001 | 05 | 2001 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $30,612 | $50,000 | Not Implemented |
NC0227 # 06 Y:2001 | 06 | 2001 | INSTALL DE-AERATOR IN PLACE OF CONDENSATE TANK | $200,000 | $35,000 | Not Implemented |
NC0227 # 07 Y:2001 | 07 | 2001 | CONTROL PRESSURE ON STEAMER OPERATIONS | $7,356 | $7,500 | Implemented |
NC0227 # 08 Y:2001 | 08 | 2001 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $4,500 | $5,000 | Not Implemented |
NC0227 # 09 Y:2001 | 09 | 2001 | ADJUST BURNERS FOR EFFICIENT OPERATION | $17,577 | $15,000 | Not Implemented |
NC0227 # 10 Y:2001 | 10 | 2001 | DEVELOP A REPAIR/REPLACE POLICY | $2,636 | $4,205 | Implemented |
NC0227 # 11 Y:2001 | 11 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,277 | $2,690 | Not Implemented |
NC0227 # 12 Y:2001 | 12 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $824 | $1,210 | Implemented |
NC0227 # 13 Y:2001 | 13 | 2001 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $8,933 | $10,067 | Implemented |
NC0227 # 14 Y:2001 | 14 | 2001 | CONDENSE OPERATION INTO ONE BUILDING | $279,320 | $500,000 | Implemented |
NC0227 # 15 Y:2001 | 15 | 2001 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $23,716 | $15,000 | Not Implemented |
UF0284 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,548 | $9,647 | Implemented |
UF0284 # 02 Y:2001 | 02 | 2001 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $17,357 | $50 | Not Implemented |
UF0284 # 03 Y:2001 | 03 | 2001 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $20,280 | $49,350 | Not Implemented |
UF0284 # 04 Y:2001 | 04 | 2001 | DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING | $6,860 | $1,212 | Not Implemented |