Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
11,853
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0192 # 01 Y:2000 | 01 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,572 | $186 | Not Implemented |
SD0249 # 01 Y:2000 | 01 | 2000 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $12,372 | $25 | Implemented |
SD0249 # 02 Y:2000 | 02 | 2000 | UPGRADE CONTROLS ON COMPRESSORS | $898 | $600 | Implemented |
SD0249 # 03 Y:2000 | 03 | 2000 | $62,250 | $100,000 | Not Implemented | |
SD0249 # 04 Y:2000 | 04 | 2000 | $25,500 | $23,000 | Not Implemented | |
NV0152 # 01 Y:2000 | 01 | 2000 | OPTIMIZE PLANT POWER FACTOR | $6,243 | $5,535 | Not Implemented |
NV0152 # 02 Y:2000 | 02 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $642 | $450 | Not Implemented |
NV0152 # 03 Y:2000 | 03 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $532 | $500 | Not Implemented |
NV0152 # 04 Y:2000 | 04 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $898 | $303 | Implemented |
NV0152 # 05 Y:2000 | 05 | 2000 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $1,244 | $0 | Implemented |
NV0152 # 06 Y:2000 | 06 | 2000 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $1,178 | $3,500 | Implemented |
SD0248 # 01 Y:2000 | 01 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $31,001 | $40,000 | Not Implemented |
SD0248 # 02 Y:2000 | 02 | 2000 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,837 | $14,800 | Implemented |
SD0248 # 03 Y:2000 | 03 | 2000 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $4,532 | $7,536 | Implemented |
SD0248 # 04 Y:2000 | 04 | 2000 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,585 | $0 | Implemented |
SD0248 # 05 Y:2000 | 05 | 2000 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,887 | $4,950 | Implemented |
SD0248 # 06 Y:2000 | 06 | 2000 | USE EVAPORATION TO CONCENTRATE MATERIAL | $5,300 | $12,500 | Not Implemented |
SD0248 # 07 Y:2000 | 07 | 2000 | $11,600 | $1,000 | Implemented | |
SD0248 # 08 Y:2000 | 08 | 2000 | $743 | $800 | Not Implemented | |
SD0248 # 09 Y:2000 | 09 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,397 | $8,500 | Implemented |
SD0248 # 10 Y:2000 | 10 | 2000 | $70,500 | $120,000 | Not Implemented | |
SD0248 # 11 Y:2000 | 11 | 2000 | $13,426 | $11,836 | Implemented | |
SF0191 # 01 Y:2000 | 01 | 2000 | INCREASE AMOUNT OF CONDENSATE RETURNED | $6,345 | $4,320 | Not Implemented |
SF0191 # 02 Y:2000 | 02 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $833 | $1,707 | Not Implemented |
SF0191 # 03 Y:2000 | 03 | 2000 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $9,529 | $32,232 | Not Implemented |