IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,996

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0130 # 02 Y:1997 02 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $184 $249 Implemented
WV0130 # 03 Y:1997 03 1997 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $391 $680 Implemented
WV0130 # 04 Y:1997 04 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $107 $110 Not Implemented
WV0130 # 05 Y:1997 05 1997 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $107 $80 Implemented
WV0130 # 06 Y:1997 06 1997 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $7,634 $5,160 Not Implemented
WV0130 # 07 Y:1997 07 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $90 $400 Not Implemented
WV0130 # 08 Y:1997 08 1997 INSTALL AUTOMATIC STACK DAMPER $1,234 $250 Not Implemented
WV0130 # 09 Y:1997 09 1997 INSTALL / REPAIR INSULATION ON STEAM LINES $82 $33 Implemented
UL0187 # 01 Y:1997 01 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $447 $20 Implemented
UL0187 # 02 Y:1997 02 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $125 $104 Not Implemented
UL0187 # 03 Y:1997 03 1997 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $1,370 $9,500 Not Implemented
UL0187 # 04 Y:1997 04 1997 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $3,640 $17,000 Not Implemented
UL0187 # 05 Y:1997 05 1997 $143,000 $13,120 Implemented
TN0620 # 01 Y:1997 01 1997 $475,880 $25,800 Implemented
TN0620 # 02 Y:1997 02 1997 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS $135,680 $47,360 Not Implemented
TN0620 # 03 Y:1997 03 1997 $9,000 $17,900 Implemented
TN0620 # 04 Y:1997 04 1997 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $7,050 $2,580 Not Implemented
TN0620 # 05 Y:1997 05 1997 INSTALL TIMERS AND/OR THERMOSTATS $6,430 $2,930 Not Implemented
TN0620 # 06 Y:1997 06 1997 ADD AREA LIGHTING SWITCHES $3,435 $8,400 Not Implemented
TN0620 # 07 Y:1997 07 1997 TURN OFF EQUIPMENT WHEN NOT IN USE $2,520 $3,700 Not Implemented
TN0620 # 08 Y:1997 08 1997 INSULATE BARE EQUIPMENT $1,000 $680 Implemented
WV0130 # 10 Y:1997 10 1997 RECOVER WASTE HEAT FROM EQUIPMENT $507 $225 Not Implemented
WV0130 # 11 Y:1997 11 1997 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $1,512 $2,300 Not Implemented
WV0130 # 12 Y:1997 12 1997 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $1,687 $11,000 Not Implemented
WV0130 # 13 Y:1997 13 1997 $47,040 $0 Implemented