Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,260
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0532 # 03 Y:2007 | 03 | 2007 | AIR CONDITION ONLY SPACE NECESSARY | $1,700 | $5,200 | Not Implemented |
AM0532 # 04 Y:2007 | 04 | 2007 | INSTALL OCCUPANCY SENSORS | $670 | $285 | Implemented |
AM0532 # 05 Y:2007 | 05 | 2007 | ADD AREA LIGHTING SWITCHES | $320 | $65 | Implemented |
MA0622 # 01 Y:2007 | 01 | 2007 | BURN A LESS EXPENSIVE GRADE OF FUEL | $1,852,277 | $4,120,500 | Implemented |
MA0622 # 02 Y:2007 | 02 | 2007 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $653,801 | $423,075 | Implemented |
MA0622 # 03 Y:2007 | 03 | 2007 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $449,650 | $250,000 | Not Implemented |
MA0622 # 04 Y:2007 | 04 | 2007 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $337,840 | $694,400 | Implemented |
MA0622 # 05 Y:2007 | 05 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $67,981 | $60,600 | Not Implemented |
MA0622 # 06 Y:2007 | 06 | 2007 | UPGRADE OBSOLETE EQUIPMENT | $34,468 | $111,500 | Implemented |
MA0622 # 07 Y:2007 | 07 | 2007 | INSTALL / REPAIR INSULATION ON STEAM LINES | $21,165 | $10,000 | Implemented |
MA0622 # 08 Y:2007 | 08 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $15,919 | $30,500 | Not Implemented |
DL0006 # 01 Y:2007 | 01 | 2007 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $3,642 | $0 | Implemented |
DL0006 # 02 Y:2007 | 02 | 2007 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $2,178 | $0 | Not Implemented |
DL0006 # 03 Y:2007 | 03 | 2007 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $6,925 | $995 | Not Implemented |
UD0766 # 01 Y:2007 | 01 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $832,000 | $400,000 | Not Implemented |
UD0766 # 02 Y:2007 | 02 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $942,000 | $520,000 | Not Implemented |
UD0766 # 03 Y:2007 | 03 | 2007 | IMPROVE COMBUSTION CONTROL CAPABILITY | $306,000 | $20,000 | Not Implemented |
UD0766 # 04 Y:2007 | 04 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $164,851 | $140,000 | Not Implemented |
UD0766 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $78,420 | $279,770 | Implemented |
UD0766 # 06 Y:2007 | 06 | 2007 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $57,000 | $30,000 | Not Implemented |
UD0766 # 07 Y:2007 | 07 | 2007 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $40,000 | $1,100 | Implemented |
UD0766 # 08 Y:2007 | 08 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $35,800 | $20,000 | Implemented |
UD0766 # 09 Y:2007 | 09 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $26,203 | $10,000 | Not Implemented |
UD0766 # 10 Y:2007 | 10 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,343 | $85,140 | Implemented |
UD0766 # 11 Y:2007 | 11 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,564 | $19,275 | Implemented |