Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,980
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0461 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,923 | $0 | Implemented |
UD0461 # 04 Y:1995 | 04 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,525 | $14,640 | Implemented |
UD0461 # 05 Y:1995 | 05 | 1995 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $3,483 | $1,000 | Implemented |
UD0461 # 06 Y:1995 | 06 | 1995 | USE EVAPORATION TO CONCENTRATE MATERIAL | $14,223 | $20,000 | Implemented |
UD0459 # 01 Y:1995 | 01 | 1995 | OPTIMIZE PLANT POWER FACTOR | $9,255 | $3,200 | Implemented |
UD0459 # 02 Y:1995 | 02 | 1995 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $9,913 | $1,000 | Implemented |
UD0459 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,174 | $2,605 | Not Implemented |
UD0459 # 04 Y:1995 | 04 | 1995 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $41,743 | $340,000 | Implemented |
UD0459 # 05 Y:1995 | 05 | 1995 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $545,061 | $4,500,000 | Implemented |
WV0061 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,417 | $1,162 | Implemented |
WV0061 # 02 Y:1995 | 02 | 1995 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $5,239 | $3,730 | Implemented |
WV0061 # 03 Y:1995 | 03 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,045 | $0 | Implemented |
WV0061 # 04 Y:1995 | 04 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,441 | $7,970 | Implemented |
WV0061 # 05 Y:1995 | 05 | 1995 | INSULATE BARE EQUIPMENT | $3,388 | $1,804 | Not Implemented |
WV0061 # 06 Y:1995 | 06 | 1995 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $6,013 | $6,000 | Not Implemented |
WV0061 # 07 Y:1995 | 07 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $229 | $90 | Not Implemented |
WV0061 # 08 Y:1995 | 08 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $384 | $670 | Not Implemented |
WV0061 # 09 Y:1995 | 09 | 1995 | USE SYNTHETIC LUBRICANT | $239 | $0 | Not Implemented |
UD0458 # 01 Y:1995 | 01 | 1995 | OPTIMIZE PLANT POWER FACTOR | $11,292 | $25,000 | Implemented |
UD0458 # 02 Y:1995 | 02 | 1995 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $22,105 | $70,000 | Not Implemented |
UD0458 # 03 Y:1995 | 03 | 1995 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $23,747 | $5,000 | Implemented |
UD0458 # 04 Y:1995 | 04 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $12,040 | $30,000 | Implemented |
UD0458 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,553 | $23,127 | Implemented |
UD0458 # 06 Y:1995 | 06 | 1995 | KEEP LAMPS AND REFLECTORS CLEAN | $2,914 | $1,680 | Implemented |
UD0458 # 07 Y:1995 | 07 | 1995 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,344 | $0 | Not Implemented |