Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,100
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0028 # 06 Y:2008 | 06 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,080 | $500 | Not Implemented |
DL0028 # 07 Y:2008 | 07 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $9,100 | $12,000 | Not Implemented |
DL0028 # 08 Y:2008 | 08 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,290 | $12,000 | Implemented |
DL0028 # 09 Y:2008 | 09 | 2008 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $1,400 | $400 | Implemented |
DL0028 # 10 Y:2008 | 10 | 2008 | USE SOLAR HEAT TO MAKE ELECTRICTY | $134,000 | $1,275,000 | Not Implemented |
DL0025 # 01 Y:2008 | 01 | 2008 | DE-ENERGIZE EXCESS TRANSFORMER CAPACITY | $1,078 | $0 | Not Implemented |
DL0025 # 02 Y:2008 | 02 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,976 | $0 | Implemented |
DL0025 # 03 Y:2008 | 03 | 2008 | TURN OFF EQUIPMENT WHEN NOT IN USE | $36,900 | $0 | Implemented |
DL0025 # 04 Y:2008 | 04 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,600 | $0 | Not Implemented |
DL0025 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,919 | $30,000 | Implemented |
DL0025 # 06 Y:2008 | 06 | 2008 | UPGRADE CONTROLS ON COMPRESSORS | $3,964 | $0 | Not Implemented |
DL0026 # 01 Y:2008 | 01 | 2008 | TURN OFF EQUIPMENT WHEN NOT IN USE | $38,000 | $0 | Implemented |
DL0026 # 02 Y:2008 | 02 | 2008 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $15,500 | $0 | Implemented |
DL0026 # 03 Y:2008 | 03 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,841 | $1,430 | Not Implemented |
DL0026 # 04 Y:2008 | 04 | 2008 | REDUCE VENTILATION AIR | $9,470 | $0 | Not Implemented |
DL0026 # 05 Y:2008 | 05 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,327 | $640 | Not Implemented |
DL0026 # 06 Y:2008 | 06 | 2008 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,600 | $2,800 | Not Implemented |
DL0026 # 07 Y:2008 | 07 | 2008 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $23,000 | $40,000 | Implemented |
DL0026 # 08 Y:2008 | 08 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,377 | $45,000 | Implemented |
DL0023 # 01 Y:2008 | 01 | 2008 | TURN OFF EQUIPMENT WHEN NOT IN USE | $26,000 | $0 | Not Implemented |
DL0023 # 02 Y:2008 | 02 | 2008 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $8,300 | $0 | Not Implemented |
DL0023 # 03 Y:2008 | 03 | 2008 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,900 | $0 | Not Implemented |
DL0023 # 04 Y:2008 | 04 | 2008 | RELOCATE OVEN / FURNACE TO MORE EFFICIENT LOCATION | $31,000 | $26,000 | Not Implemented |
DL0023 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,500 | $22,600 | Not Implemented |
DL0023 # 06 Y:2008 | 06 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,400 | $500 | Not Implemented |