Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,377
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0168 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $68 | $912 | Not Implemented |
KU0168 # 04 Y:1985 | 04 | 1985 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $140 | $0 | Not Implemented |
KU0169 # 01 Y:1985 | 01 | 1985 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $1,536,415 | $7,700,000 | Not Implemented |
KU0169 # 02 Y:1985 | 02 | 1985 | INSULATE BARE EQUIPMENT | $48,005 | $6,000 | Implemented |
KU0169 # 03 Y:1985 | 03 | 1985 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $13,083 | $5,000 | Implemented |
KU0169 # 04 Y:1985 | 04 | 1985 | OPTIMIZE PLANT POWER FACTOR | $7,711 | $37,000 | Implemented |
KU0169 # 05 Y:1985 | 05 | 1985 | INSTALL SET-BACK TIMERS | $8,360 | $622 | Implemented |
KU0169 # 06 Y:1985 | 06 | 1985 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $7,219 | $13,000 | Implemented |
KU0169 # 07 Y:1985 | 07 | 1985 | INSTALL AUTOMATIC STACK DAMPER | $4,581 | $1,700 | Implemented |
KU0169 # 08 Y:1985 | 08 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,579 | $0 | Implemented |
KU0169 # 09 Y:1985 | 09 | 1985 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,472 | $500 | Implemented |
KU0169 # 10 Y:1985 | 10 | 1985 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,251 | $1,600 | Not Implemented |
KU0169 # 11 Y:1985 | 11 | 1985 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,590 | $50 | Not Implemented |
KU0169 # 12 Y:1985 | 12 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,444 | $550 | Implemented |
KU0169 # 13 Y:1985 | 13 | 1985 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,374 | $580 | Implemented |
KU0169 # 14 Y:1985 | 14 | 1985 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $605 | $0 | Implemented |
KU0169 # 15 Y:1985 | 15 | 1985 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $598 | $50 | Implemented |
KU0169 # 16 Y:1985 | 16 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $549 | $660 | Implemented |
KU0169 # 17 Y:1985 | 17 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $218 | $40 | Not Implemented |
KU0170 # 01 Y:1985 | 01 | 1985 | BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT | $97,361 | $494,400 | Not Implemented |
KU0170 # 02 Y:1985 | 02 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $29,255 | $18 | Implemented |
KU0170 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,755 | $2,656 | Implemented |
KU0170 # 04 Y:1985 | 04 | 1985 | REPAIR AND ELIMINATE STEAM LEAKS | $5,297 | $300 | Implemented |
KU0170 # 05 Y:1985 | 05 | 1985 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,901 | $6,000 | Implemented |
KU0170 # 06 Y:1985 | 06 | 1985 | INCREASE AMOUNT OF CONDENSATE RETURNED | $1,746 | $1,000 | Implemented |