Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

9,942

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0419 # 03 Y:1993 03 1993 RECOVER WASTE HEAT FROM EQUIPMENT $3,741 $2,000 Not Implemented
UD0419 # 04 Y:1993 04 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,200 $5,739 Implemented
UD0419 # 05 Y:1993 05 1993 CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS $81,110 $0 Implemented
UD0419 # 06 Y:1993 06 1993 RECOVER WASTE HEAT FROM EQUIPMENT $27,720 $60,000 Not Implemented
UD0419 # 07 Y:1993 07 1993 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $89,581 $20,000 Implemented
UD0418 # 01 Y:1993 01 1993 PAY UTILITY BILLS ON TIME $2,115 $0 Not Implemented
UD0418 # 02 Y:1993 02 1993 OPTIMIZE PLANT POWER FACTOR $14,702 $9,250 Implemented
UD0418 # 03 Y:1993 03 1993 INSTALL EFFICIENT RECTIFIERS $1,456 $15,000 Implemented
UD0418 # 04 Y:1993 04 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $6,180 $4,000 Implemented
UD0418 # 05 Y:1993 05 1993 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $31,259 $6,000 Implemented
UD0418 # 06 Y:1993 06 1993 RECOVER AND REUSE COOLING WATER $12,300 $1,000 Implemented
UD0417 # 01 Y:1993 01 1993 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $5,791 $0 Not Implemented
UD0417 # 02 Y:1993 02 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $191 $937 Not Implemented
UD0417 # 03 Y:1993 03 1993 USE DEMAND CONTROLLER OR LOAD SHEDDER $57,131 $250 Not Implemented
UD0416 # 01 Y:1993 01 1993 USE DEMAND CONTROLLER OR LOAD SHEDDER $2,440 $0 Not Implemented
UD0416 # 02 Y:1993 02 1993 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $17,440 $20,000 Not Implemented
UD0416 # 03 Y:1993 03 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,163 $2,170 Implemented
UD0416 # 04 Y:1993 04 1993 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM $9,061 $3,000 Implemented
UD0416 # 05 Y:1993 05 1993 TURN OFF EQUIPMENT WHEN NOT IN USE $2,209 $0 Not Implemented
UD0415 # 01 Y:1993 01 1993 USE DEMAND CONTROLLER OR LOAD SHEDDER $7,569 $0 Not Implemented
UD0415 # 02 Y:1993 02 1993 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $8,020 $3,000 Implemented
UD0415 # 03 Y:1993 03 1993 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $200,000 $480,000 Not Implemented
UD0415 # 04 Y:1993 04 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,314 $31,350 Implemented
UD0415 # 05 Y:1993 05 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,263 $5,400 Not Implemented
UD0415 # 06 Y:1993 06 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,514 $3,200 Not Implemented