IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,443

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0510 # 07 Y:1998 07 1998 UTILIZE A CENTRAL COOLANT SYSTEM FOR CLEANING AND REUSE OF METAL WORKING FLUID $3,900 $11,720 Not Implemented
KU0510 # 08 Y:1998 08 1998 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS $1,350 $2,310 Implemented
IA0210 # 01 Y:1998 01 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,138 $17,423 Implemented
IA0210 # 02 Y:1998 02 1998 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $4,040 $12,186 Not Implemented
IA0210 # 03 Y:1998 03 1998 INSTALL OCCUPANCY SENSORS $2,457 $2,793 Implemented
IA0210 # 04 Y:1998 04 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,766 $4,820 Implemented
IA0210 # 05 Y:1998 05 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $134 $282 Implemented
IA0210 # 06 Y:1998 06 1998 MOVE PRODUCT USING MECHANICAL MEANS $261,385 $19,800 Not Implemented
IA0210 # 07 Y:1998 07 1998 USE RADIANT HEATER FOR SPOT HEATING $2,824 $10,101 Not Implemented
IA0197 # 01 Y:1998 01 1998 AUTOMATE FINISHING PROCESS $234,000 $280,000 n/a
IA0197 # 02 Y:1998 02 1998 INSTALL AUTOMATIC PACKING EQUIPMENT $185,000 $340,000 n/a
IA0197 # 03 Y:1998 03 1998 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $22,403 $27,855 n/a
IA0197 # 04 Y:1998 04 1998 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $9,995 $4,200 n/a
IA0197 # 05 Y:1998 05 1998 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $8,880 $0 n/a
IA0197 # 06 Y:1998 06 1998 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,626 $25 n/a
IA0197 # 07 Y:1998 07 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,902 $13,293 n/a
IA0197 # 08 Y:1998 08 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,437 $4,274 n/a
IA0197 # 09 Y:1998 09 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,886 $200 n/a
IA0197 # 10 Y:1998 10 1998 INSTALL OCCUPANCY SENSORS $667 $931 n/a
IA0195 # 01 Y:1998 01 1998 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $19,062 $6,300 Implemented
IA0195 # 02 Y:1998 02 1998 USE DEMAND CONTROLLER OR LOAD SHEDDER $15,886 $2,000 Implemented
IA0195 # 03 Y:1998 03 1998 MOVE PRODUCT USING MECHANICAL MEANS $15,300 $8,676 Not Implemented
IA0195 # 04 Y:1998 04 1998 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $2,783 $500 Implemented
IA0195 # 05 Y:1998 05 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,336 $130 Implemented
IA0195 # 06 Y:1998 06 1998 RECOVER MECHANICAL ENERGY $2,321 $3,413 Implemented