Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,443
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0510 # 07 Y:1998 | 07 | 1998 | UTILIZE A CENTRAL COOLANT SYSTEM FOR CLEANING AND REUSE OF METAL WORKING FLUID | $3,900 | $11,720 | Not Implemented |
KU0510 # 08 Y:1998 | 08 | 1998 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $1,350 | $2,310 | Implemented |
IA0210 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,138 | $17,423 | Implemented |
IA0210 # 02 Y:1998 | 02 | 1998 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $4,040 | $12,186 | Not Implemented |
IA0210 # 03 Y:1998 | 03 | 1998 | INSTALL OCCUPANCY SENSORS | $2,457 | $2,793 | Implemented |
IA0210 # 04 Y:1998 | 04 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,766 | $4,820 | Implemented |
IA0210 # 05 Y:1998 | 05 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $134 | $282 | Implemented |
IA0210 # 06 Y:1998 | 06 | 1998 | MOVE PRODUCT USING MECHANICAL MEANS | $261,385 | $19,800 | Not Implemented |
IA0210 # 07 Y:1998 | 07 | 1998 | USE RADIANT HEATER FOR SPOT HEATING | $2,824 | $10,101 | Not Implemented |
IA0197 # 01 Y:1998 | 01 | 1998 | AUTOMATE FINISHING PROCESS | $234,000 | $280,000 | n/a |
IA0197 # 02 Y:1998 | 02 | 1998 | INSTALL AUTOMATIC PACKING EQUIPMENT | $185,000 | $340,000 | n/a |
IA0197 # 03 Y:1998 | 03 | 1998 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $22,403 | $27,855 | n/a |
IA0197 # 04 Y:1998 | 04 | 1998 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $9,995 | $4,200 | n/a |
IA0197 # 05 Y:1998 | 05 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $8,880 | $0 | n/a |
IA0197 # 06 Y:1998 | 06 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,626 | $25 | n/a |
IA0197 # 07 Y:1998 | 07 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,902 | $13,293 | n/a |
IA0197 # 08 Y:1998 | 08 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,437 | $4,274 | n/a |
IA0197 # 09 Y:1998 | 09 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,886 | $200 | n/a |
IA0197 # 10 Y:1998 | 10 | 1998 | INSTALL OCCUPANCY SENSORS | $667 | $931 | n/a |
IA0195 # 01 Y:1998 | 01 | 1998 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $19,062 | $6,300 | Implemented |
IA0195 # 02 Y:1998 | 02 | 1998 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $15,886 | $2,000 | Implemented |
IA0195 # 03 Y:1998 | 03 | 1998 | MOVE PRODUCT USING MECHANICAL MEANS | $15,300 | $8,676 | Not Implemented |
IA0195 # 04 Y:1998 | 04 | 1998 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $2,783 | $500 | Implemented |
IA0195 # 05 Y:1998 | 05 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,336 | $130 | Implemented |
IA0195 # 06 Y:1998 | 06 | 1998 | RECOVER MECHANICAL ENERGY | $2,321 | $3,413 | Implemented |