Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,063
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0005 # 05 Y:2007 | 05 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $24,677 | $10,000 | Not Implemented |
DL0005 # 06 Y:2007 | 06 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $37,314 | $108,987 | Implemented |
DL0005 # 07 Y:2007 | 07 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $15,951 | $80,000 | Not Implemented |
DL0004 # 01 Y:2007 | 01 | 2007 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $39,666 | $0 | Implemented |
DL0004 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $33,000 | $97,570 | Not Implemented |
DL0004 # 03 Y:2007 | 03 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,160 | $800 | Not Implemented |
DL0004 # 04 Y:2007 | 04 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,933 | $500 | Not Implemented |
DL0004 # 05 Y:2007 | 05 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,506 | $33,000 | Not Implemented |
DL0004 # 06 Y:2007 | 06 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $93,700 | $130,000 | Not Implemented |
DL0004 # 07 Y:2007 | 07 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,203 | $8,830 | Not Implemented |
DL0001 # 01 Y:2007 | 01 | 2007 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $93,802 | $111,140 | Not Implemented |
DL0001 # 02 Y:2007 | 02 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,151 | $13,790 | Implemented |
DL0001 # 03 Y:2007 | 03 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $59,111 | $104,392 | Implemented |
DL0001 # 04 Y:2007 | 04 | 2007 | INSULATE BARE EQUIPMENT | $44,733 | $12,474 | Not Implemented |
DL0001 # 05 Y:2007 | 05 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,582 | $620 | Not Implemented |
DL0001 # 06 Y:2007 | 06 | 2007 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $29,521 | $0 | Not Implemented |
DL0001 # 07 Y:2007 | 07 | 2007 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $2,976 | $5,832 | Not Implemented |
LE0243 # 01 Y:2006 | 01 | 2006 | INSTALL WASTE HEAT BOILER TO PRODUCE STEAM | $193,808 | $200,000 | Not Implemented |
LE0243 # 02 Y:2006 | 02 | 2006 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $28,291 | $86,000 | Not Implemented |
LE0243 # 03 Y:2006 | 03 | 2006 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $27,533 | $20,000 | Not Implemented |
LE0243 # 04 Y:2006 | 04 | 2006 | AIR CONDITION ONLY SPACE NECESSARY | $27,306 | $200 | Not Implemented |
LE0243 # 05 Y:2006 | 05 | 2006 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $18,286 | $50,000 | Not Implemented |
LE0243 # 06 Y:2006 | 06 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $8,730 | $2,400 | Not Implemented |
LE0243 # 07 Y:2006 | 07 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,824 | $80 | Not Implemented |
LE0243 # 08 Y:2006 | 08 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,925 | $2,000 | Not Implemented |