Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,642
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0205 # 01 Y:2015 | 01 | 2015 | INSULATE BARE EQUIPMENT | $771 | $1,050 | Not Implemented |
MZ0205 # 02 Y:2015 | 02 | 2015 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $1,559 | $0 | Implemented |
MZ0205 # 03 Y:2015 | 03 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,581 | $850 | Implemented |
MZ0205 # 04 Y:2015 | 04 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $397 | $0 | Implemented |
MZ0205 # 05 Y:2015 | 05 | 2015 | INSTALL OCCUPANCY SENSORS | $969 | $400 | Implemented |
MZ0197 # 01 Y:2015 | 01 | 2015 | INSTALL OCCUPANCY SENSORS | $5,337 | $1,752 | Implemented |
MZ0197 # 02 Y:2015 | 02 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,900 | $960 | Implemented |
MZ0197 # 03 Y:2015 | 03 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $11,344 | $3,200 | Implemented |
MZ0197 # 04 Y:2015 | 04 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,362 | $1,160 | Implemented |
MZ0197 # 05 Y:2015 | 05 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,151 | $0 | Not Implemented |
MZ0193 # 01 Y:2015 | 01 | 2015 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $21,804 | $700 | Implemented |
MZ0193 # 02 Y:2015 | 02 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,714 | $1,160 | Implemented |
MZ0193 # 03 Y:2015 | 03 | 2015 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $62,777 | $37,500 | Implemented |
MZ0193 # 04 Y:2015 | 04 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,733 | $5,660 | Not Implemented |
MZ0192 # 01 Y:2015 | 01 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,801 | $1,160 | Implemented |
MZ0192 # 02 Y:2015 | 02 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $11,360 | $6,100 | Implemented |
MZ0192 # 03 Y:2015 | 03 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,247 | $920 | Implemented |
MZ0192 # 04 Y:2015 | 04 | 2015 | REPLACE HIGH RESISTANCE DUCTS, PIPES, AND FITTINGS | $8,654 | $19,200 | Not Implemented |
MZ0192 # 05 Y:2015 | 05 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,211 | $0 | Implemented |
MZ0194 # 01 Y:2015 | 01 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,734 | $6,785 | Not Implemented |
MZ0194 # 02 Y:2015 | 02 | 2015 | INSTALL OCCUPANCY SENSORS | $1,023 | $610 | Not Implemented |
MZ0194 # 03 Y:2015 | 03 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,332 | $4,400 | Not Implemented |
MZ0199 # 01 Y:2015 | 01 | 2015 | CONDENSE OPERATION INTO ONE BUILDING | $14,201 | $28,800 | Not Implemented |
MZ0199 # 02 Y:2015 | 02 | 2015 | CONDENSE OPERATION INTO ONE BUILDING | $19,376 | $2,500 | Not Implemented |
MZ0199 # 03 Y:2015 | 03 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31,470 | $116,250 | Not Implemented |