Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,260
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0325 # 05 Y:2007 | 05 | 2007 | INSULATE BARE EQUIPMENT | $7,856 | $4,379 | Not Implemented |
UM0325 # 06 Y:2007 | 06 | 2007 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $7,729 | $1,620 | Implemented |
UM0325 # 07 Y:2007 | 07 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,586 | $2,640 | Not Implemented |
UM0325 # 08 Y:2007 | 08 | 2007 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,151 | $1,000 | Not Implemented |
UM0325 # 09 Y:2007 | 09 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $701 | $400 | Not Implemented |
UW0007 # 01 Y:2007 | 01 | 2007 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $15,370 | $62,800 | Implemented |
UW0007 # 02 Y:2007 | 02 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,257 | $3,146 | Not Implemented |
UW0007 # 03 Y:2007 | 03 | 2007 | USE SOLAR HEAT TO MAKE ELECTRICTY | $1,315 | $585 | Not Implemented |
UW0007 # 04 Y:2007 | 04 | 2007 | INSTALL OCCUPANCY SENSORS | $98 | $355 | Implemented |
SU0258 # 01 Y:2007 | 01 | 2007 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $16,481 | $0 | Not Implemented |
SU0258 # 02 Y:2007 | 02 | 2007 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $3,129 | $0 | Not Implemented |
SU0258 # 03 Y:2007 | 03 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,056 | $0 | Implemented |
SU0258 # 04 Y:2007 | 04 | 2007 | USE SYNTHETIC LUBRICANT | $659 | $0 | Implemented |
SU0258 # 05 Y:2007 | 05 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $111 | $0 | Implemented |
SU0258 # 06 Y:2007 | 06 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,250 | $149 | Implemented |
SU0258 # 07 Y:2007 | 07 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $914 | $160 | Implemented |
SU0258 # 08 Y:2007 | 08 | 2007 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $213,621 | $114,259 | Not Implemented |
SU0258 # 09 Y:2007 | 09 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $491 | $469 | Implemented |
SU0258 # 10 Y:2007 | 10 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,446 | $4,400 | Implemented |
SU0258 # 11 Y:2007 | 11 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,915 | $2,847 | Not Implemented |
SU0258 # 12 Y:2007 | 12 | 2007 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $197 | $344 | Not Implemented |
SU0258 # 13 Y:2007 | 13 | 2007 | INSTALL OCCUPANCY SENSORS | $112 | $357 | Implemented |
SU0258 # 14 Y:2007 | 14 | 2007 | OPTIMIZE PLANT POWER FACTOR | $1,080 | $9,965 | Not Implemented |
WV0364 # 01 Y:2007 | 01 | 2007 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $37,506 | $7,700 | Not Implemented |
WV0364 # 02 Y:2007 | 02 | 2007 | INSULATE BARE EQUIPMENT | $29,507 | $12,903 | Implemented |