Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,703

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0637 # 02 Y:2014 02 2014 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $9,404 $10,529 Not Implemented
OR0637 # 03 Y:2014 03 2014 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,677 $1,971 Not Implemented
OK0896 # 01 Y:2014 01 2014 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,242 $1,588 Not Implemented
OK0896 # 02 Y:2014 02 2014 RECOVER WASTE HEAT FROM EQUIPMENT $6,653 $1,751 Implemented
OK0896 # 03 Y:2014 03 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,702 $400 Implemented
OK0896 # 04 Y:2014 04 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,435 $16,592 Not Implemented
OK0896 # 05 Y:2014 05 2014 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $9,020 $43,252 Not Implemented
OK0896 # 06 Y:2014 06 2014 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $13,523 $7,700 Not Implemented
OK0896 # 07 Y:2014 07 2014 INSTALL TIMERS AND/OR THERMOSTATS $746 $169 Implemented
OK0896 # 08 Y:2014 08 2014 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,458 $28,800 Not Implemented
OK0896 # 09 Y:2014 09 2014 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,826 $9,200 Not Implemented
OR0636 # 01 Y:2014 01 2014 IMPROVE COMBUSTION CONTROL CAPABILITY $31,057 $7,123 Not Implemented
OR0636 # 02 Y:2014 02 2014 UPGRADE OBSOLETE EQUIPMENT $55,473 $50,000 Not Implemented
OR0636 # 03 Y:2014 03 2014 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $5,708 $7,000 Implemented
OR0636 # 04 Y:2014 04 2014 REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE $27,166 $37,500 Not Implemented
OR0636 # 05 Y:2014 05 2014 MINIMIZE CONTAMINATION OF WATER BEFORE TREATMENT $712,265 $3,300,000 Not Implemented
NC0524 # 01 Y:2014 01 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,264 $42,866 Implemented
NC0524 # 02 Y:2014 02 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $19,056 $100 Implemented
NC0524 # 03 Y:2014 03 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $10,368 $100 Implemented
NC0524 # 04 Y:2014 04 2014 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $7,341 $29,000 Not Implemented
NC0524 # 05 Y:2014 05 2014 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $606 $300 Implemented
NC0524 # 06 Y:2014 06 2014 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,243 $475 Implemented
NC0524 # 07 Y:2014 07 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,355 $3,984 Implemented
NC0524 # 08 Y:2014 08 2014 INSTALL OCCUPANCY SENSORS $1,948 $3,644 Implemented
NC0524 # 09 Y:2014 09 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $550 $160 Implemented