Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,642
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0171 # 01 Y:2015 | 01 | 2015 | AIR CONDITION ONLY SPACE NECESSARY | $1,588 | $0 | Not Implemented |
MZ0171 # 02 Y:2015 | 02 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $8,781 | $0 | Not Implemented |
MZ0171 # 03 Y:2015 | 03 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,759 | $3,900 | Not Implemented |
MZ0171 # 04 Y:2015 | 04 | 2015 | INSTALL OCCUPANCY SENSORS | $2,783 | $880 | Not Implemented |
MZ0171 # 05 Y:2015 | 05 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,558 | $870 | Not Implemented |
MZ0198 # 01 Y:2015 | 01 | 2015 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,716 | $0 | Not Implemented |
MZ0198 # 02 Y:2015 | 02 | 2015 | INSULATE BARE EQUIPMENT | $1,728 | $1,750 | Not Implemented |
MZ0198 # 03 Y:2015 | 03 | 2015 | INSTALL OCCUPANCY SENSORS | $10,113 | $2,500 | Not Implemented |
MZ0198 # 04 Y:2015 | 04 | 2015 | CONDENSE OPERATION INTO ONE BUILDING | $17,298 | $1,040 | Implemented |
MZ0198 # 05 Y:2015 | 05 | 2015 | INSTALL OCCUPANCY SENSORS | $915 | $250 | Not Implemented |
MZ0198 # 06 Y:2015 | 06 | 2015 | UPGRADE CONTROLS ON COMPRESSORS | $4,180 | $17,000 | Not Implemented |
MZ0198 # 07 Y:2015 | 07 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,611 | $1,500 | Implemented |
MZ0188 # 01 Y:2015 | 01 | 2015 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $19,385 | $0 | Implemented |
MZ0188 # 02 Y:2015 | 02 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,967 | $10,000 | Not Implemented |
MZ0188 # 03 Y:2015 | 03 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,249 | $1,000 | Implemented |
MZ0188 # 04 Y:2015 | 04 | 2015 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,811 | $0 | Implemented |
MZ0183 # 01 Y:2015 | 01 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $847 | $1,500 | Not Implemented |
MZ0183 # 02 Y:2015 | 02 | 2015 | ELIMINATE/REDUCE AN OPERATION | $562 | $0 | Not Implemented |
MZ0183 # 03 Y:2015 | 03 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,085 | $980 | Not Implemented |
MZ0183 # 04 Y:2015 | 04 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,266 | $3,750 | Not Implemented |
MZ0183 # 05 Y:2015 | 05 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,719 | $10,000 | Not Implemented |
MZ0183 # 06 Y:2015 | 06 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $852 | $0 | Not Implemented |
MZ0185 # 01 Y:2015 | 01 | 2015 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $444,193 | $2,686,745 | Not Implemented |
MZ0185 # 02 Y:2015 | 02 | 2015 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $4,593 | $7,228 | Implemented |
MZ0185 # 03 Y:2015 | 03 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $16,223 | $0 | Not Implemented |