Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,942
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0098 # 02 Y:1983 | 02 | 1983 | INSTALL STORM WINDOWS AND DOORS | $9,286 | $8,000 | Not Implemented |
UD0098 # 03 Y:1983 | 03 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $992 | $590 | Not Implemented |
UD0098 # 04 Y:1983 | 04 | 1983 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $6,313 | $11,424 | Not Implemented |
UD0098 # 05 Y:1983 | 05 | 1983 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,383 | $0 | Not Implemented |
UD0099 # 01 Y:1983 | 01 | 1983 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $4,571 | $10,000 | Not Implemented |
UD0099 # 02 Y:1983 | 02 | 1983 | INSTALL TIMERS AND/OR THERMOSTATS | $9,454 | $4,000 | Not Implemented |
UD0099 # 03 Y:1983 | 03 | 1983 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $633 | $0 | Not Implemented |
UD0090 # 01 Y:1983 | 01 | 1983 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $5,380 | $8,000 | Not Implemented |
UD0090 # 02 Y:1983 | 02 | 1983 | USE IMMERSION HEATING IN TANKS, MELTING POTS, ETC | $1,074 | $1,300 | Not Implemented |
UD0090 # 03 Y:1983 | 03 | 1983 | INSTALL STORM WINDOWS AND DOORS | $703 | $100 | Implemented |
UD0090 # 04 Y:1983 | 04 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,164 | $785 | Not Implemented |
UD0090 # 05 Y:1983 | 05 | 1983 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $183 | $0 | Implemented |
UD0091 # 01 Y:1983 | 01 | 1983 | CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS | $13,041 | $4,710 | Not Implemented |
UD0091 # 02 Y:1983 | 02 | 1983 | INSTALL TIMERS AND/OR THERMOSTATS | $11,682 | $4,000 | Not Implemented |
UD0091 # 03 Y:1983 | 03 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,369 | $2,467 | Not Implemented |
UD0091 # 04 Y:1983 | 04 | 1983 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $3,053 | $6,225 | Not Implemented |
UD0091 # 05 Y:1983 | 05 | 1983 | INSTALL STORM WINDOWS AND DOORS | $1,186 | $2,252 | Not Implemented |
UD0091 # 06 Y:1983 | 06 | 1983 | REDESIGN PROCESS | $13,696 | $30,000 | Implemented |
UD0092 # 01 Y:1983 | 01 | 1983 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,885 | $200 | Not Implemented |
UD0092 # 02 Y:1983 | 02 | 1983 | INSTALL STORM WINDOWS AND DOORS | $4,277 | $8,800 | Not Implemented |
UD0092 # 03 Y:1983 | 03 | 1983 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,757 | $250 | Not Implemented |
UD0092 # 04 Y:1983 | 04 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,590 | $1,300 | Not Implemented |
UD0093 # 01 Y:1983 | 01 | 1983 | BURN WOOD BY-PRODUCTS FOR HEAT | $33,271 | $53,040 | Not Implemented |
UD0093 # 02 Y:1983 | 02 | 1983 | INSTALL STORM WINDOWS AND DOORS | $12,137 | $7,918 | Implemented |
UD0093 # 03 Y:1983 | 03 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,042 | $5,758 | Implemented |