Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,317
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0451 # 04 Y:2012 | 04 | 2012 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $4,597 | $27,000 | Not Implemented |
WV0451 # 05 Y:2012 | 05 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,858 | $380 | Implemented |
WV0451 # 06 Y:2012 | 06 | 2012 | INSULATE BARE EQUIPMENT | $3,732 | $1,737 | Implemented |
WV0451 # 07 Y:2012 | 07 | 2012 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,357 | $5,400 | Not Implemented |
WV0451 # 08 Y:2012 | 08 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,273 | $10,200 | Implemented |
WV0451 # 09 Y:2012 | 09 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,705 | $9,700 | Not Implemented |
WV0451 # 10 Y:2012 | 10 | 2012 | DEVELOP A REPAIR/REPLACE POLICY | $2,628 | $640 | Not Implemented |
WV0451 # 11 Y:2012 | 11 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,982 | $9,000 | Not Implemented |
WV0451 # 12 Y:2012 | 12 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,612 | $1,260 | Not Implemented |
WV0451 # 13 Y:2012 | 13 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,600 | $2,500 | Implemented |
WV0451 # 14 Y:2012 | 14 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,239 | $5,054 | Not Implemented |
WV0451 # 15 Y:2012 | 15 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,001 | $467 | Not Implemented |
WV0451 # 16 Y:2012 | 16 | 2012 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $783 | $70 | Implemented |
WV0449 # 01 Y:2012 | 01 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,142 | $3,345 | Not Implemented |
WV0449 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,722 | $23,208 | Implemented |
WV0449 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,929 | $13,233 | Implemented |
WV0449 # 04 Y:2012 | 04 | 2012 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $3,821 | $1,000 | Implemented |
WV0449 # 05 Y:2012 | 05 | 2012 | USE SYNTHETIC LUBRICANT | $3,043 | $500 | Not Implemented |
WV0449 # 06 Y:2012 | 06 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,472 | $4,330 | Not Implemented |
WV0449 # 07 Y:2012 | 07 | 2012 | DEVELOP A REPAIR/REPLACE POLICY | $2,133 | $637 | Implemented |
WV0449 # 08 Y:2012 | 08 | 2012 | INSTALL TIMERS AND/OR THERMOSTATS | $1,302 | $605 | Not Implemented |
WV0449 # 09 Y:2012 | 09 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,258 | $1,084 | Not Implemented |
WV0449 # 10 Y:2012 | 10 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $808 | $1,242 | Not Implemented |
WV0449 # 11 Y:2012 | 11 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $803 | $1,484 | Not Implemented |
WV0449 # 12 Y:2012 | 12 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $734 | $1,630 | Not Implemented |