Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,403
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0376 # 06 Y:1996 | 06 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,320 | $350 | Implemented |
CO0376 # 07 Y:1996 | 07 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $650 | $2,620 | Implemented |
DS0072 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,015 | $67,277 | Not Implemented |
DS0072 # 02 Y:1996 | 02 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,927 | $675 | Implemented |
DS0072 # 03 Y:1996 | 03 | 1996 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,689 | $1,110 | Implemented |
DS0072 # 04 Y:1996 | 04 | 1996 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $5,139 | $10,000 | Not Implemented |
DS0072 # 05 Y:1996 | 05 | 1996 | INSULATE BARE EQUIPMENT | $3,328 | $3,572 | Not Implemented |
DS0072 # 06 Y:1996 | 06 | 1996 | MINIMIZE WATER USAGE | $5,755 | $3,000 | Implemented |
DS0070 # 01 Y:1996 | 01 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $3,276 | $4,750 | Not Implemented |
DS0070 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,725 | $11,774 | Not Implemented |
DS0070 # 03 Y:1996 | 03 | 1996 | RECOVER AND REUSE WASTE MATERIAL | $544 | $0 | Not Implemented |
DS0070 # 04 Y:1996 | 04 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $181 | $0 | Implemented |
DS0070 # 05 Y:1996 | 05 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $1,684 | $2,310 | Implemented |
DS0071 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,865 | $9,854 | Not Implemented |
DS0071 # 02 Y:1996 | 02 | 1996 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $8,572 | $42,350 | Not Implemented |
DS0071 # 03 Y:1996 | 03 | 1996 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $12,255 | $0 | Implemented |
DS0071 # 04 Y:1996 | 04 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,703 | $750 | Implemented |
NC0087 # 01 Y:1996 | 01 | 1996 | REDUCE VENTILATION AIR | $1,513 | $4,305 | Not Implemented |
NC0087 # 02 Y:1996 | 02 | 1996 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $965 | $0 | Not Implemented |
NC0087 # 03 Y:1996 | 03 | 1996 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $862 | $1,500 | Implemented |
NC0087 # 04 Y:1996 | 04 | 1996 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,789 | $2,100 | Implemented |
NC0087 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $796 | $1,839 | Not Implemented |
NC0087 # 06 Y:1996 | 06 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $487 | $2,100 | Not Implemented |
NC0087 # 07 Y:1996 | 07 | 1996 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $10,542 | $1,800 | Implemented |
NC0087 # 08 Y:1996 | 08 | 1996 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $94 | $750 | Implemented |