Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,417
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
RU0093 # 03 Y:1990 | 03 | 1990 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,109 | $1,900 | Not Implemented |
RU0093 # 04 Y:1990 | 04 | 1990 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,811 | $2,500 | Implemented |
RU0093 # 05 Y:1990 | 05 | 1990 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $4,019 | $0 | Not Implemented |
RU0093 # 06 Y:1990 | 06 | 1990 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $227 | $550 | Not Implemented |
RU0093 # 07 Y:1990 | 07 | 1990 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $5,411 | $1,920 | Not Implemented |
TN0399 # 01 Y:1990 | 01 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,222 | $2,750 | Implemented |
TN0399 # 02 Y:1990 | 02 | 1990 | REDUCE VENTILATION AIR | $5,547 | $5,692 | Not Implemented |
TN0399 # 03 Y:1990 | 03 | 1990 | INSTALL / REPAIR INSULATION ON STEAM LINES | $825 | $687 | Implemented |
TN0399 # 04 Y:1990 | 04 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,844 | $900 | Implemented |
TN0399 # 05 Y:1990 | 05 | 1990 | USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS | $6,555 | $16,100 | Not Implemented |
TN0399 # 06 Y:1990 | 06 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $1,873 | $185 | Implemented |
TN0399 # 07 Y:1990 | 07 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $416 | $96 | Implemented |
TN0399 # 08 Y:1990 | 08 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $813 | $680 | Implemented |
TN0399 # 09 Y:1990 | 09 | 1990 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $583 | $210 | Implemented |
TN0399 # 10 Y:1990 | 10 | 1990 | OPTIMIZE PLANT POWER FACTOR | $4,690 | $5,900 | Not Implemented |
MA0182 # 01 Y:1990 | 01 | 1990 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $5,921 | $116,600 | Implemented |
MA0182 # 02 Y:1990 | 02 | 1990 | INSTALL SET-BACK TIMERS | $368 | $440 | Implemented |
MA0182 # 03 Y:1990 | 03 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $678 | $336 | Implemented |
MA0182 # 04 Y:1990 | 04 | 1990 | INSULATE BARE EQUIPMENT | $644 | $1,540 | Not Implemented |
MA0182 # 05 Y:1990 | 05 | 1990 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $471 | $675 | Implemented |
MA0182 # 06 Y:1990 | 06 | 1990 | REDUCE VENTILATION AIR | $2,509 | $500 | Not Implemented |
MA0185 # 01 Y:1990 | 01 | 1990 | OPTIMIZE PLANT POWER FACTOR | $9,738 | $10,200 | Implemented |
MA0185 # 02 Y:1990 | 02 | 1990 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,358 | $0 | Not Implemented |
MA0185 # 03 Y:1990 | 03 | 1990 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $334 | $180 | Implemented |
MA0185 # 04 Y:1990 | 04 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $340 | $471 | Implemented |