Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,640
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TA0014 # 03 Y:2001 | 03 | 2001 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,675 | $170 | Implemented |
TA0014 # 04 Y:2001 | 04 | 2001 | INSTALL OCCUPANCY SENSORS | $1,516 | $320 | Implemented |
TA0014 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,011 | $989 | Implemented |
TA0014 # 06 Y:2001 | 06 | 2001 | INSTALL / REPAIR INSULATION ON STEAM LINES | $663 | $150 | Not Implemented |
TA0014 # 07 Y:2001 | 07 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $185 | $345 | Implemented |
CO0491 # 01 Y:2001 | 01 | 2001 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $20,780 | $61,010 | Implemented |
CO0491 # 02 Y:2001 | 02 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,820 | $4,110 | Not Implemented |
CO0491 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,740 | $570 | Implemented |
CO0491 # 04 Y:2001 | 04 | 2001 | DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING | $3,630 | $1,000 | Not Implemented |
CO0491 # 05 Y:2001 | 05 | 2001 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,870 | $1,300 | Implemented |
CO0491 # 06 Y:2001 | 06 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,550 | $0 | Not Implemented |
CO0491 # 07 Y:2001 | 07 | 2001 | INSTALL OCCUPANCY SENSORS | $220 | $210 | Not Implemented |
CO0491 # 08 Y:2001 | 08 | 2001 | INSTALL BACK-UP EQUIPMENT | $54,170 | $84,380 | Implemented |
WI0406 # 01 Y:2001 | 01 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $8,841 | $0 | Implemented |
WI0406 # 02 Y:2001 | 02 | 2001 | OPTIMIZE PLANT POWER FACTOR | $7,981 | $14,550 | Not Implemented |
WI0406 # 03 Y:2001 | 03 | 2001 | INSTALL TIMERS AND/OR THERMOSTATS | $3,632 | $600 | Not Implemented |
WI0406 # 04 Y:2001 | 04 | 2001 | INSTALL OCCUPANCY SENSORS | $3,556 | $3,880 | Not Implemented |
WI0406 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,901 | $0 | Not Implemented |
WI0406 # 06 Y:2001 | 06 | 2001 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $1,063 | $0 | Not Implemented |
WI0406 # 07 Y:2001 | 07 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $392 | $556 | Not Implemented |
IA0278 # 01 Y:2001 | 01 | 2001 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $32,729 | $0 | n/a |
IA0278 # 02 Y:2001 | 02 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,244 | $407 | n/a |
IA0278 # 03 Y:2001 | 03 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,906 | $222 | n/a |
IA0278 # 04 Y:2001 | 04 | 2001 | INSTALL OCCUPANCY SENSORS | $8,703 | $19,781 | n/a |
IA0278 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,749 | $15,786 | n/a |