IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,130

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0281 # 01 Y:1993 01 1993 USE RADIANT HEATER FOR SPOT HEATING $19,600 $64,900 Not Implemented
CO0281 # 02 Y:1993 02 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,830 $18,320 Not Implemented
CO0281 # 03 Y:1993 03 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,790 $150 Not Implemented
CO0281 # 04 Y:1993 04 1993 REDUCE VENTILATION AIR $1,450 $1,050 Not Implemented
CO0281 # 05 Y:1993 05 1993 INSTALL TIMERS AND/OR THERMOSTATS $1,100 $1,370 Not Implemented
CO0281 # 06 Y:1993 06 1993 USE POWER DURING OFF-PEAK PERIODS $890 $360 Not Implemented
CO0281 # 07 Y:1993 07 1993 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $880 $50 Not Implemented
UD0412 # 01 Y:1993 01 1993 USE DEMAND CONTROLLER OR LOAD SHEDDER $1,246 $0 Not Implemented
UD0412 # 02 Y:1993 02 1993 USE DEMAND CONTROLLER OR LOAD SHEDDER $2,409 $0 Implemented
UD0412 # 03 Y:1993 03 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,119 $3,091 Not Implemented
UD0412 # 04 Y:1993 04 1993 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $9,600 $0 Not Implemented
AS0099 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,057 $0 Implemented
AS0099 # 02 Y:1993 02 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $408 $324 Not Implemented
AS0099 # 03 Y:1993 03 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $869 $1,740 Implemented
AS0099 # 04 Y:1993 04 1993 USE PHOTOCELL CONTROLS $1,567 $950 Not Implemented
AS0099 # 05 Y:1993 05 1993 INSTALL OCCUPANCY SENSORS $893 $1,200 Not Implemented
AS0099 # 06 Y:1993 06 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,919 $900 Implemented
AS0099 # 07 Y:1993 07 1993 USE SYNTHETIC LUBRICANT $2,881 $2,925 Not Implemented
AS0099 # 08 Y:1993 08 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,581 $3,412 Implemented
AS0099 # 09 Y:1993 09 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $10,126 $0 Not Implemented
AS0099 # 10 Y:1993 10 1993 UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM $1,614 $4,250 Not Implemented
AS0099 # 11 Y:1993 11 1993 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $198 $600 Not Implemented
AS0099 # 12 Y:1993 12 1993 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $50,576 $50,000 Not Implemented
ND0155 # 01 Y:1993 01 1993 INCREASE AMOUNT OF CONDENSATE RETURNED $105,938 $35,500 Not Implemented
ND0155 # 02 Y:1993 02 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,600 $4,745 Implemented