Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,314
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0405 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,782 | $4,000 | Not Implemented |
AS0405 # 05 Y:2005 | 05 | 2005 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $5,719 | $120 | Not Implemented |
AS0405 # 06 Y:2005 | 06 | 2005 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $867 | $3,000 | Not Implemented |
AS0405 # 07 Y:2005 | 07 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $573 | $612 | Not Implemented |
AS0403 # 01 Y:2005 | 01 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,641 | $1,000 | Not Implemented |
AS0403 # 02 Y:2005 | 02 | 2005 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $16,622 | $10,000 | Not Implemented |
AS0403 # 03 Y:2005 | 03 | 2005 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $15,050 | $2,000 | Not Implemented |
AS0403 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,834 | $27,518 | Not Implemented |
AS0403 # 05 Y:2005 | 05 | 2005 | USE SOLAR HEAT TO HEAT WATER | $580 | $3,600 | Not Implemented |
AS0402 # 01 Y:2005 | 01 | 2005 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $15,919 | $11,000 | Implemented |
AS0402 # 02 Y:2005 | 02 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $13,755 | $1,000 | Implemented |
AS0402 # 03 Y:2005 | 03 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $12,630 | $1,000 | Implemented |
AS0402 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,620 | $50,533 | Implemented |
AS0402 # 05 Y:2005 | 05 | 2005 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $4,823 | $1,000 | Not Implemented |
AS0402 # 06 Y:2005 | 06 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $4,059 | $18,400 | Implemented |
AS0402 # 07 Y:2005 | 07 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,059 | $2,000 | Not Implemented |
AS0402 # 08 Y:2005 | 08 | 2005 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $687 | $3,000 | Not Implemented |
AS0398 # 01 Y:2005 | 01 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,000 | $2,000 | Not Implemented |
AS0398 # 02 Y:2005 | 02 | 2005 | OPTIMIZE PLANT POWER FACTOR | $749,532 | $6,404,000 | Not Implemented |
AS0398 # 03 Y:2005 | 03 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,293 | $2,902 | Not Implemented |
AS0398 # 04 Y:2005 | 04 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $811 | $0 | Not Implemented |
AS0398 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,184 | $4,984 | Not Implemented |
AS0398 # 06 Y:2005 | 06 | 2005 | INSTALL SENSORS TO DETECT AND AVOID JAMS | $251,744 | $8,000 | Not Implemented |
AS0401 # 01 Y:2005 | 01 | 2005 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $129,307 | $21,049 | Not Implemented |
AS0401 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,061 | $7,690 | Not Implemented |