IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,150

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0070 # 01 Y:1983 01 1983 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,791 $60 Implemented
OK0070 # 02 Y:1983 02 1983 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $297 $392 Implemented
OK0070 # 03 Y:1983 03 1983 INSTALL TIMERS AND/OR THERMOSTATS $163 $475 Not Implemented
OK0070 # 04 Y:1983 04 1983 INSTALL TIMERS AND/OR THERMOSTATS $197 $475 Not Implemented
OK0070 # 05 Y:1983 05 1983 INSTALL SET-BACK TIMERS $4,660 $14,963 Implemented
OK0070 # 06 Y:1983 06 1983 USE RADIANT HEATER FOR SPOT HEATING $3,156 $1,000 Implemented
OK0070 # 07 Y:1983 07 1983 OPTIMIZE PLANT POWER FACTOR $1,612 $2,173 Implemented
OK0070 # 08 Y:1983 08 1983 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $9,064 $53,000 Not Implemented
OK0071 # 01 Y:1983 01 1983 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,264 $160 Not Implemented
UD0071 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,990 $627 Not Implemented
UD0071 # 02 Y:1983 02 1983 INSTALL STORM WINDOWS AND DOORS $1,451 $2,000 Not Implemented
UD0071 # 03 Y:1983 03 1983 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $2,364 $3,680 Implemented
UD0071 # 04 Y:1983 04 1983 RECOVER WASTE HEAT FROM EQUIPMENT $6,519 $40,000 Not Implemented
UD0072 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,588 $581 Implemented
UD0072 # 02 Y:1983 02 1983 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $71,594 $288,000 Not Implemented
UD0072 # 03 Y:1983 03 1983 RECOVER WASTE HEAT FROM EQUIPMENT $6,416 $518 Implemented
UD0072 # 04 Y:1983 04 1983 UPGRADE OBSOLETE EQUIPMENT $5,762 $20,000 Not Implemented
UD0072 # 05 Y:1983 05 1983 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $174 $0 Implemented
UD0072 # 06 Y:1983 06 1983 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $88,910 $155,000 Not Implemented
UD0072 # 07 Y:1983 07 1983 UPGRADE OBSOLETE EQUIPMENT $17,289 $0 Implemented
UD0073 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,488 $150 Not Implemented
UD0073 # 02 Y:1983 02 1983 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $7,396 $37,500 Not Implemented
UD0073 # 03 Y:1983 03 1983 AIR CONDITION ONLY SPACE NECESSARY $356 $375 Not Implemented
UD0074 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,071 $698 Implemented
UD0074 # 02 Y:1983 02 1983 INSTALL STORM WINDOWS AND DOORS $22,216 $32,456 Not Implemented