Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,756
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0791 # 04 Y:2018 | 04 | 2018 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $974 | $1,000 | Implemented |
MA0791 # 05 Y:2018 | 05 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $434 | $200 | Not Implemented |
AM0757 # 01 Y:2018 | 01 | 2018 | TURN OFF EQUIPMENT WHEN NOT IN USE | $65,410 | $255 | Implemented |
AM0757 # 02 Y:2018 | 02 | 2018 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $12,154 | $1,140 | Implemented |
AM0757 # 03 Y:2018 | 03 | 2018 | OPTIMIZE PLANT POWER FACTOR | $25,420 | $82,110 | Not Implemented |
AM0757 # 04 Y:2018 | 04 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,856 | $3,000 | Implemented |
AM0757 # 05 Y:2018 | 05 | 2018 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $47,160 | $136 | Implemented |
AM0757 # 06 Y:2018 | 06 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,069 | $28,981 | Implemented |
AM0757 # 07 Y:2018 | 07 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,340 | $17 | Implemented |
LE0457 # 01 Y:2018 | 01 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,554 | $25,157 | Implemented |
LE0457 # 02 Y:2018 | 02 | 2018 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $619 | $2,200 | Not Implemented |
LE0457 # 03 Y:2018 | 03 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,771 | $10,041 | Implemented |
LE0457 # 04 Y:2018 | 04 | 2018 | REPLACE BOILER | $33,772 | $150,000 | Not Implemented |
LE0457 # 05 Y:2018 | 05 | 2018 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $2,689 | $13,000 | Implemented |
LE0457 # 06 Y:2018 | 06 | 2018 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $4,457 | $36,000 | Implemented |
WM0125 # 01 Y:2018 | 01 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,273 | $13,601 | Not Implemented |
WM0125 # 02 Y:2018 | 02 | 2018 | USE SOLAR HEAT TO MAKE ELECTRICTY | $17,677 | $48,514 | Not Implemented |
WM0125 # 03 Y:2018 | 03 | 2018 | USE SYNTHETIC LUBRICANT | $11,015 | $21,250 | Not Implemented |
WM0125 # 04 Y:2018 | 04 | 2018 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,087 | $2,215 | Implemented |
WM0125 # 05 Y:2018 | 05 | 2018 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,042 | $1,525 | Not Implemented |
WM0125 # 06 Y:2018 | 06 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $791 | $1,806 | Not Implemented |
WM0125 # 07 Y:2018 | 07 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $293 | $0 | Implemented |
WM0125 # 08 Y:2018 | 08 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $284 | $360 | Not Implemented |
WM0125 # 09 Y:2018 | 09 | 2018 | INSTALL OCCUPANCY SENSORS | $200 | $855 | Not Implemented |
WM0125 # 10 Y:2018 | 10 | 2018 | INSTALL OCCUPANCY SENSORS | $86 | $136 | Not Implemented |