Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,380
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0055 # 06 Y:1989 | 06 | 1989 | OPTIMIZE PLANT POWER FACTOR | $3,950 | $8,400 | Implemented |
OR0055 # 07 Y:1989 | 07 | 1989 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $333 | $1,000 | Not Implemented |
OR0056 # 01 Y:1989 | 01 | 1989 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $252 | $0 | Implemented |
OR0056 # 02 Y:1989 | 02 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,873 | $100 | Implemented |
OR0056 # 03 Y:1989 | 03 | 1989 | MINIMIZE WATER USAGE | $3,946 | $1,683 | Implemented |
OR0056 # 04 Y:1989 | 04 | 1989 | KEEP BOILER TUBES CLEAN | $1,821 | $100 | Implemented |
OR0056 # 05 Y:1989 | 05 | 1989 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $377 | $310 | Not Implemented |
OR0056 # 06 Y:1989 | 06 | 1989 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $3,201 | $2,750 | Implemented |
OR0056 # 07 Y:1989 | 07 | 1989 | OPTIMIZE PLANT POWER FACTOR | $294 | $750 | Not Implemented |
OR0057 # 01 Y:1989 | 01 | 1989 | INCREASE AMOUNT OF CONDENSATE RETURNED | $2,420 | $870 | Implemented |
OR0057 # 02 Y:1989 | 02 | 1989 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $201 | $145 | Implemented |
OR0057 # 03 Y:1989 | 03 | 1989 | OPTIMIZE PLANT POWER FACTOR | $6,061 | $5,850 | Implemented |
OR0057 # 04 Y:1989 | 04 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $308 | $389 | Implemented |
OR0057 # 05 Y:1989 | 05 | 1989 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $1,219 | $1,903 | Not Implemented |
OR0057 # 06 Y:1989 | 06 | 1989 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $6,972 | $28,690 | Not Implemented |
OR0057 # 07 Y:1989 | 07 | 1989 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $2,159 | $6,871 | Not Implemented |
WI0058 # 01 Y:1989 | 01 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $20,838 | $3,000 | Implemented |
WI0058 # 02 Y:1989 | 02 | 1989 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $6,185 | $20,000 | Not Implemented |
WI0058 # 03 Y:1989 | 03 | 1989 | IMPROVE LUBRICATION PRACTICES | $7,226 | $0 | Implemented |
WI0058 # 04 Y:1989 | 04 | 1989 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $5,645 | $4,200 | Not Implemented |
WI0058 # 05 Y:1989 | 05 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,077 | $500 | Implemented |
WI0058 # 06 Y:1989 | 06 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,523 | $0 | Implemented |
WI0058 # 07 Y:1989 | 07 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,585 | $1,500 | Implemented |
WI0058 # 08 Y:1989 | 08 | 1989 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,395 | $800 | Not Implemented |
WI0058 # 09 Y:1989 | 09 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $668 | $0 | Implemented |