Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,043
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0866 # 03 Y:2013 | 03 | 2013 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $19,312 | $184,080 | Not Implemented |
OK0866 # 04 Y:2013 | 04 | 2013 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $4,776 | $1,440 | Implemented |
OK0866 # 05 Y:2013 | 05 | 2013 | INSTALL SET-BACK TIMERS | $449 | $318 | Implemented |
OK0866 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $865 | $3,992 | Not Implemented |
OK0866 # 07 Y:2013 | 07 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,853 | $22,216 | Not Implemented |
OK0866 # 08 Y:2013 | 08 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $299 | $463 | Not Implemented |
OK0866 # 09 Y:2013 | 09 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,915 | $2,598 | Not Implemented |
OK0866 # 10 Y:2013 | 10 | 2013 | INCREASE AMOUNT OF CONDENSATE RETURNED | $1,019 | $700 | Not Implemented |
OK0866 # 11 Y:2013 | 11 | 2013 | INSULATE BARE EQUIPMENT | $232 | $280 | Implemented |
OK0866 # 12 Y:2013 | 12 | 2013 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $2,408 | $2,686 | Not Implemented |
OK0866 # 13 Y:2013 | 13 | 2013 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $189 | $2,098 | Not Implemented |
OK0866 # 14 Y:2013 | 14 | 2013 | REDUCE HEAT GAIN BY WINDOW TINTING | $1,077 | $16,000 | Implemented |
TT0116 # 01 Y:2013 | 01 | 2013 | OPTIMIZE PLANT POWER FACTOR | $1,609 | $5,920 | Not Implemented |
TT0116 # 02 Y:2013 | 02 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $837 | $763 | Not Implemented |
TT0116 # 03 Y:2013 | 03 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,077 | $700 | Not Implemented |
TT0116 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,073 | $12,258 | Implemented |
NC0494 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,160 | $7,564 | Not Implemented |
NC0494 # 02 Y:2013 | 02 | 2013 | INSTALL OCCUPANCY SENSORS | $1,833 | $1,524 | Not Implemented |
NC0494 # 03 Y:2013 | 03 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $195 | $61 | Not Implemented |
NC0494 # 04 Y:2013 | 04 | 2013 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,051 | $825 | Not Implemented |
NC0494 # 05 Y:2013 | 05 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $950 | $4,258 | Not Implemented |
NC0494 # 06 Y:2013 | 06 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $856 | $820 | Not Implemented |
NC0494 # 07 Y:2013 | 07 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $410 | $100 | Not Implemented |
LE0366 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $264,361 | $119,173 | Not Implemented |
LE0366 # 02 Y:2013 | 02 | 2013 | USE OPTIMUM THICKNESS INSULATION | $45,077 | $26,012 | Not Implemented |