IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,443

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0205 # 03 Y:1991 03 1991 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $5,600 $500 Not Implemented
CO0205 # 04 Y:1991 04 1991 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,100 $2,000 Not Implemented
CO0205 # 05 Y:1991 05 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,600 $400 Not Implemented
CO0205 # 06 Y:1991 06 1991 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,300 $3,100 Not Implemented
CO0205 # 07 Y:1991 07 1991 INSTALL TIMERS AND/OR THERMOSTATS $440 $300 Not Implemented
KU0323 # 01 Y:1990 01 1990 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $832 $987 Not Implemented
KU0323 # 02 Y:1990 02 1990 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $560 $220 Not Implemented
KU0323 # 03 Y:1990 03 1990 INSULATE BARE EQUIPMENT $201 $120 Implemented
KU0324 # 01 Y:1990 01 1990 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $1,876 $410 Not Implemented
KU0324 # 02 Y:1990 02 1990 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE $1,759 $4,000 Implemented
KU0324 # 03 Y:1990 03 1990 INSTALL SET-BACK TIMERS $821 $600 Not Implemented
KU0324 # 04 Y:1990 04 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $544 $0 Implemented
KU0324 # 05 Y:1990 05 1990 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $139 $0 Not Implemented
KU0318 # 01 Y:1990 01 1990 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $39,803 $0 Implemented
KU0318 # 02 Y:1990 02 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,872 $1,000 Implemented
KU0318 # 03 Y:1990 03 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $713 $741 Implemented
KU0318 # 04 Y:1990 04 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $74 $90 Implemented
KU0318 # 05 Y:1990 05 1990 RECOVER AND REUSE COOLING WATER $65,074 $27,000 Not Implemented
KU0318 # 06 Y:1990 06 1990 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $61,404 $0 Implemented
KU0318 # 07 Y:1990 07 1990 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM $1,283 $3,200 Not Implemented
KU0320 # 01 Y:1990 01 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $891 $828 Implemented
KU0320 # 02 Y:1990 02 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,152 $3,325 Implemented
KU0320 # 03 Y:1990 03 1990 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $4,842 $9,000 Implemented
KU0320 # 04 Y:1990 04 1990 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $1,845 $1,500 Implemented
KU0320 # 05 Y:1990 05 1990 UTILIZE SENSORS CONTROLLING ROOF AND WALL OPENINGS $2,154 $2,300 Not Implemented