Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,380
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0379 # 06 Y:1989 | 06 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $234 | $0 | Not Implemented |
GT0379 # 07 Y:1989 | 07 | 1989 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $369 | $850 | Not Implemented |
GT0380 # 01 Y:1989 | 01 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $7,220 | $18,000 | Implemented |
GT0380 # 02 Y:1989 | 02 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $542 | $0 | Implemented |
GT0380 # 03 Y:1989 | 03 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $336 | $183 | Implemented |
GT0380 # 04 Y:1989 | 04 | 1989 | KEEP LAMPS AND REFLECTORS CLEAN | $3,750 | $14,410 | Not Implemented |
GT0380 # 05 Y:1989 | 05 | 1989 | INSTALL SET-BACK TIMERS | $370 | $0 | Not Implemented |
GT0380 # 06 Y:1989 | 06 | 1989 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $4,550 | $0 | Not Implemented |
GT0380 # 07 Y:1989 | 07 | 1989 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $3,560 | $4,000 | Implemented |
GT0380 # 08 Y:1989 | 08 | 1989 | USE RADIANT HEATER FOR SPOT HEATING | $3,840 | $19,500 | Implemented |
GT0380 # 09 Y:1989 | 09 | 1989 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,600 | $29,600 | Not Implemented |
AM0067 # 01 Y:1989 | 01 | 1989 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $28,911 | $6,400 | Not Implemented |
AM0067 # 02 Y:1989 | 02 | 1989 | REPAIR AND ELIMINATE STEAM LEAKS | $4,380 | $800 | Implemented |
AM0067 # 03 Y:1989 | 03 | 1989 | INSTALL SET-BACK TIMERS | $3,860 | $0 | Implemented |
AM0067 # 04 Y:1989 | 04 | 1989 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $2,932 | $175 | Implemented |
AM0067 # 06 Y:1989 | 06 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $900 | $800 | Not Implemented |
AM0067 # 07 Y:1989 | 07 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $154 | $91 | Not Implemented |
AM0067 # 08 Y:1989 | 08 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $285 | $83 | Not Implemented |
AM0067 # 09 Y:1989 | 09 | 1989 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $94 | $500 | Not Implemented |
AM0068 # 01 Y:1989 | 01 | 1989 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $40,430 | $24,600 | Implemented |
AM0068 # 02 Y:1989 | 02 | 1989 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $9,210 | $16,500 | Implemented |
AM0068 # 03 Y:1989 | 03 | 1989 | INSTALL SET-BACK TIMERS | $2,180 | $0 | Implemented |
AM0068 # 04 Y:1989 | 04 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $890 | $1,000 | Implemented |
AM0068 # 05 Y:1989 | 05 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $347 | $97 | Implemented |
AM0068 # 06 Y:1989 | 06 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $330 | $295 | Implemented |