Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
144,065
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0310 # 05 Y:1994 | 05 | 1994 | USE IN-PROCESS RECYCLING WHENEVER POSSIBLE | $1,840 | $0 | Implemented |
CO0310 # 06 Y:1994 | 06 | 1994 | REDUCE VENTILATION AIR | $850 | $550 | Implemented |
CO0310 # 07 Y:1994 | 07 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $440 | $730 | Implemented |
CO0310 # 08 Y:1994 | 08 | 1994 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $410 | $90 | Implemented |
NC0035 # 01 Y:1994 | 01 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,391 | $1,620 | Implemented |
NC0035 # 02 Y:1994 | 02 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,132 | $700 | Not Implemented |
NC0035 # 03 Y:1994 | 03 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,131 | $500 | Not Implemented |
NC0035 # 04 Y:1994 | 04 | 1994 | TURN OFF EQUIPMENT WHEN NOT IN USE | $824 | $0 | Implemented |
NC0035 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,711 | $1,085 | Not Implemented |
NC0035 # 06 Y:1994 | 06 | 1994 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $664 | $820 | Not Implemented |
NC0035 # 07 Y:1994 | 07 | 1994 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $7,987 | $17,200 | Not Implemented |
NC0035 # 08 Y:1994 | 08 | 1994 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,639 | $2,000 | Not Implemented |
NC0035 # 09 Y:1994 | 09 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,960 | $9,280 | Implemented |
NC0035 # 10 Y:1994 | 10 | 1994 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $6,023 | $3,650 | Not Implemented |
SD0094 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $606 | $520 | Implemented |
SD0094 # 02 Y:1994 | 02 | 1994 | INSULATE BARE EQUIPMENT | $438 | $64 | Not Implemented |
SD0094 # 03 Y:1994 | 03 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,453 | $28,531 | Implemented |
SD0094 # 04 Y:1994 | 04 | 1994 | INSTALL OCCUPANCY SENSORS | $9,696 | $9,890 | Not Implemented |
WV0045 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $530 | $740 | Implemented |
WV0045 # 02 Y:1994 | 02 | 1994 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $2,284 | $960 | Not Implemented |
WV0045 # 03 Y:1994 | 03 | 1994 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,030 | $4,400 | Not Implemented |
WV0045 # 04 Y:1994 | 04 | 1994 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,270 | $960 | Implemented |
WV0045 # 05 Y:1994 | 05 | 1994 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $960 | $18 | Implemented |
WV0045 # 06 Y:1994 | 06 | 1994 | USE SYNTHETIC LUBRICANT | $156 | $0 | Not Implemented |
WV0045 # 07 Y:1994 | 07 | 1994 | INSTALL TIMERS AND/OR THERMOSTATS | $1,511 | $900 | Implemented |