Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,002
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0420 # 01 Y:2012 | 01 | 2012 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $113,599 | $0 | Not Implemented |
SF0420 # 02 Y:2012 | 02 | 2012 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $17,363 | $0 | Not Implemented |
SF0420 # 03 Y:2012 | 03 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,156 | $840 | Implemented |
SF0420 # 04 Y:2012 | 04 | 2012 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $44,796 | $12,500 | Not Implemented |
SF0420 # 05 Y:2012 | 05 | 2012 | INSTALL / REPAIR INSULATION ON STEAM LINES | $936 | $555 | Implemented |
SF0420 # 06 Y:2012 | 06 | 2012 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $2,415 | $2,286 | Not Implemented |
SF0420 # 07 Y:2012 | 07 | 2012 | INCREASE AMOUNT OF CONDENSATE RETURNED | $13,612 | $13,418 | Not Implemented |
SF0420 # 08 Y:2012 | 08 | 2012 | INSTALL OCCUPANCY SENSORS | $53,028 | $57,435 | Not Implemented |
SF0420 # 09 Y:2012 | 09 | 2012 | BURN A LESS EXPENSIVE GRADE OF FUEL | $52,423 | $78,900 | Not Implemented |
SF0420 # 10 Y:2012 | 10 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,461 | $9,543 | Not Implemented |
SF0420 # 11 Y:2012 | 11 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $147,442 | $498,340 | Not Implemented |
SF0420 # 12 Y:2012 | 12 | 2012 | MINIMIZE WATER USAGE | $5,598 | $0 | Not Implemented |
SF0420 # 13 Y:2012 | 13 | 2012 | MINIMIZE WATER USAGE | $677 | $0 | Not Implemented |
CO0663 # 01 Y:2012 | 01 | 2012 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $17,080 | $500 | Implemented |
CO0663 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,450 | $32,050 | Implemented |
CO0663 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,190 | $34,790 | Implemented |
CO0663 # 04 Y:2012 | 04 | 2012 | INSTALL OCCUPANCY SENSORS | $5,150 | $11,150 | Not Implemented |
CO0663 # 05 Y:2012 | 05 | 2012 | USE SOLAR HEAT TO MAKE ELECTRICTY | $2,770 | $32,500 | Not Implemented |
MAS027 # 01 Y:2012 | 01 | 2012 | REDUCE VENTILATION AIR | $23,907 | $33,500 | Not Implemented |
MAS027 # 02 Y:2012 | 02 | 2012 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $11,449 | $28,000 | Not Implemented |
MAS027 # 03 Y:2012 | 03 | 2012 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $2,336 | $500 | Not Implemented |
UA3022 # 01 Y:2012 | 01 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $54,140 | $50 | Not Implemented |
UA3022 # 02 Y:2012 | 02 | 2012 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $31,511 | $15,063 | Not Implemented |
UA3022 # 03 Y:2012 | 03 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $12,180 | $50 | Not Implemented |
UA3022 # 04 Y:2012 | 04 | 2012 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $64,995 | $90,750 | Not Implemented |