Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

146,354

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AT0065 # 07 Y:1987 07 1987 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $1,196 $1,800 Not Implemented
AT0065 # 08 Y:1987 08 1987 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $306 $500 Implemented
OK0213 # 01 Y:1987 01 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $100 $62 Implemented
OK0213 # 02 Y:1987 02 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $70 $146 Implemented
OK0213 # 03 Y:1987 03 1987 USE DEMAND CONTROLLER OR LOAD SHEDDER $2,542 $510 Not Implemented
OK0213 # 04 Y:1987 04 1987 USE RADIANT HEATER FOR SPOT HEATING $817 $3,200 Implemented
OK0213 # 05 Y:1987 05 1987 INSTALL TIMERS AND/OR THERMOSTATS $473 $450 Not Implemented
OK0214 # 01 Y:1987 01 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $57 $43 Implemented
OK0214 # 02 Y:1987 02 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,929 $24,647 Implemented
OK0214 # 03 Y:1987 03 1987 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $638 $0 Implemented
OK0214 # 04 Y:1987 04 1987 RECOVER WASTE HEAT FROM EQUIPMENT $7,800 $1,155 Not Implemented
OK0214 # 05 Y:1987 05 1987 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,319 $0 Implemented
OK0214 # 06 Y:1987 06 1987 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $870 $230 Not Implemented
OK0214 # 07 Y:1987 07 1987 INSTALL TIMERS AND/OR THERMOSTATS $1,059 $450 Implemented
OK0215 # 01 Y:1987 01 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,613 $229 Not Implemented
OK0215 # 02 Y:1987 02 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $538 $631 Not Implemented
OK0215 # 03 Y:1987 03 1987 USE RADIANT HEATER FOR SPOT HEATING $2,478 $7,000 Not Implemented
OK0215 # 04 Y:1987 04 1987 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $211 $0 Implemented
UD0223 # 01 Y:1987 01 1987 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $6,084 $0 Implemented
UD0223 # 02 Y:1987 02 1987 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $1,302 $131 Implemented
UD0223 # 03 Y:1987 03 1987 INSTALL SET-BACK TIMERS $809 $100 Implemented
UD0224 # 01 Y:1987 01 1987 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $4,584 $0 Not Implemented
UD0224 # 02 Y:1987 02 1987 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $2,048 $7,200 Not Implemented
UD0224 # 03 Y:1987 03 1987 RECOVER WASTE HEAT FROM EQUIPMENT $2,509 $6,000 Not Implemented
UD0224 # 04 Y:1987 04 1987 REDUCE GLAZED AREAS IN BUILDINGS $3,429 $5,800 Not Implemented