Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,872
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0326 # 02 Y:1998 | 02 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,000 | $0 | Not Implemented |
OR0326 # 03 Y:1998 | 03 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,653 | $1,000 | Implemented |
OR0326 # 04 Y:1998 | 04 | 1998 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,856 | $1,210 | Implemented |
OR0326 # 05 Y:1998 | 05 | 1998 | ADJUST BURNERS FOR EFFICIENT OPERATION | $1,680 | $405 | Not Implemented |
OR0326 # 06 Y:1998 | 06 | 1998 | OPTIMIZE PLANT POWER FACTOR | $1,559 | $10,400 | Not Implemented |
OR0326 # 07 Y:1998 | 07 | 1998 | USE OTHER WASTE CONCENTRATION METHODS | $20,930 | $13,295 | Implemented |
OR0326 # 08 Y:1998 | 08 | 1998 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $5,920 | $3,680 | Not Implemented |
NV0113 # 01 Y:1998 | 01 | 1998 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $2,386 | $333 | Not Implemented |
NV0113 # 02 Y:1998 | 02 | 1998 | INSULATE BARE EQUIPMENT | $845 | $546 | Not Implemented |
NV0113 # 03 Y:1998 | 03 | 1998 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $278,123 | $520,000 | Implemented |
NV0113 # 04 Y:1998 | 04 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $390 | $0 | Implemented |
NV0113 # 05 Y:1998 | 05 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,185 | $10,360 | Not Implemented |
NV0113 # 06 Y:1998 | 06 | 1998 | INSTALL SKYLIGHTS | $643 | $2,443 | Not Implemented |
NV0113 # 07 Y:1998 | 07 | 1998 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $21,011 | $0 | Implemented |
NV0113 # 08 Y:1998 | 08 | 1998 | USE SOLAR HEAT TO HEAT WATER | $2,095 | $0 | Not Implemented |
AS0228 # 01 Y:1998 | 01 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $244,239 | $410,200 | Implemented |
AS0228 # 02 Y:1998 | 02 | 1998 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $955,252 | $4,000,000 | Not Implemented |
AS0228 # 03 Y:1998 | 03 | 1998 | USE WASTE HEAT STEAM FOR ABSORPTION REFRIGERATION | $395,073 | $1,524,052 | Not Implemented |
AS0228 # 04 Y:1998 | 04 | 1998 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $17,372 | $80,000 | Not Implemented |
AS0228 # 05 Y:1998 | 05 | 1998 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $69,699 | $225,000 | Not Implemented |
AS0228 # 06 Y:1998 | 06 | 1998 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $768 | $60 | Not Implemented |
AS0228 # 07 Y:1998 | 07 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $12,819 | $60 | Not Implemented |
AS0228 # 08 Y:1998 | 08 | 1998 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $65,562 | $7,000 | Not Implemented |
AS0228 # 09 Y:1998 | 09 | 1998 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $498,755 | $240 | Implemented |
AS0228 # 10 Y:1998 | 10 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $6,873 | $3,125 | Implemented |