Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,260
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0749 # 08 Y:2007 | 08 | 2007 | OPERATE BOILERS ON HIGH FIRE SETTING | $238,762 | $50,000 | Not Implemented |
TT0007 # 01 Y:2007 | 01 | 2007 | USE COMPRESSOR AIR FILTERS | $25,442 | $42,225 | Not Implemented |
TT0007 # 02 Y:2007 | 02 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,000 | $10,900 | Not Implemented |
TT0007 # 03 Y:2007 | 03 | 2007 | USE COMPRESSOR AIR FILTERS | $20,463 | $2,000 | Not Implemented |
TT0007 # 04 Y:2007 | 04 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $38,638 | $57,958 | Not Implemented |
TT0007 # 05 Y:2007 | 05 | 2007 | REPAIR OR REPLACE STEAM TRAPS | $13,341 | $4,000 | Not Implemented |
TT0007 # 06 Y:2007 | 06 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,294 | $480 | Not Implemented |
TT0007 # 07 Y:2007 | 07 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $46,892 | $73,290 | Not Implemented |
DL0005 # 01 Y:2007 | 01 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,373 | $0 | Implemented |
DL0005 # 02 Y:2007 | 02 | 2007 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $167,986 | $65,000 | Implemented |
DL0005 # 03 Y:2007 | 03 | 2007 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $92,780 | $18,375 | Implemented |
DL0005 # 04 Y:2007 | 04 | 2007 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $6,554 | $1,772 | Implemented |
DL0005 # 05 Y:2007 | 05 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $24,677 | $10,000 | Not Implemented |
DL0005 # 06 Y:2007 | 06 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $37,314 | $108,987 | Implemented |
DL0005 # 07 Y:2007 | 07 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $15,951 | $80,000 | Not Implemented |
UM0321 # 01 Y:2007 | 01 | 2007 | USE HEAT PUMP FOR SPACE CONDITIONING | $33,455 | $21,730 | Not Implemented |
UM0321 # 02 Y:2007 | 02 | 2007 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $11,520 | $21,700 | Not Implemented |
UM0321 # 03 Y:2007 | 03 | 2007 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $9,993 | $1,000 | Implemented |
UM0321 # 04 Y:2007 | 04 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,307 | $1,000 | Implemented |
UM0321 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,338 | $0 | Implemented |
UM0321 # 06 Y:2007 | 06 | 2007 | TREAT AND REUSE RINSE WATERS | $3,084 | $8,021 | Not Implemented |
UM0321 # 07 Y:2007 | 07 | 2007 | INSTALL OCCUPANCY SENSORS | $1,558 | $5,130 | Implemented |
MZ0008 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,856 | $21,050 | Implemented |
MZ0008 # 02 Y:2007 | 02 | 2007 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $44,772 | $6,399 | Implemented |
MZ0008 # 03 Y:2007 | 03 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,289 | $800 | Implemented |