Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,597
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0970 # 03 Y:2017 | 03 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,577 | $49,400 | Not Implemented |
UD0970 # 04 Y:2017 | 04 | 2017 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,698 | $2,000 | Not Implemented |
UD0970 # 05 Y:2017 | 05 | 2017 | ADD AREA LIGHTING SWITCHES | $541 | $250 | Implemented |
UD0970 # 06 Y:2017 | 06 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,745 | $1,000 | Not Implemented |
UD0970 # 07 Y:2017 | 07 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $298 | $1,000 | Implemented |
UD0970 # 08 Y:2017 | 08 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $164 | $50 | Not Implemented |
UU0120 # 01 Y:2017 | 01 | 2017 | CONVERT TO AIR ASSISTED / AIRLESS PAINT GUNS | $113,750 | $5,600 | Not Implemented |
UU0120 # 02 Y:2017 | 02 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $35,587 | $61,481 | Implemented |
UU0120 # 03 Y:2017 | 03 | 2017 | INSULATE BARE EQUIPMENT | $32,948 | $23,006 | Not Implemented |
UU0120 # 04 Y:2017 | 04 | 2017 | UPGRADE CONTROLS ON COMPRESSORS | $12,184 | $800 | Implemented |
UU0120 # 05 Y:2017 | 05 | 2017 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $6,334 | $400 | Implemented |
UU0120 # 06 Y:2017 | 06 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,227 | $410 | Implemented |
UU0120 # 07 Y:2017 | 07 | 2017 | INSTALL COMMON HEADER ON COMPRESSORS | $4,024 | $5,000 | Implemented |
UU0120 # 08 Y:2017 | 08 | 2017 | OPTIMIZE PLANT POWER FACTOR | $3,894 | $3,500 | Not Implemented |
UU0120 # 09 Y:2017 | 09 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,929 | $0 | Implemented |
NC0595 # 01 Y:2017 | 01 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $29,435 | $144,553 | Not Implemented |
NC0595 # 02 Y:2017 | 02 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $896 | $100 | Implemented |
NC0595 # 03 Y:2017 | 03 | 2017 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $375 | $552 | Implemented |
NC0595 # 04 Y:2017 | 04 | 2017 | ISOLATE STEAM LINES TO AVOID HEATING AIR CONDITIONED AREAS | $3,516 | $400 | Implemented |
NC0595 # 05 Y:2017 | 05 | 2017 | RECOVER WASTE HEAT FROM EQUIPMENT | $910 | $2,000 | Not Implemented |
MA0780 # 01 Y:2017 | 01 | 2017 | USE SOLAR HEAT FOR HEAT | $66,074 | $629,413 | Not Implemented |
MA0780 # 02 Y:2017 | 02 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $583 | $100 | Not Implemented |
MA0780 # 03 Y:2017 | 03 | 2017 | USE OPTIMUM THICKNESS INSULATION | $575 | $865 | Not Implemented |
MI0316 # 01 Y:2017 | 01 | 2017 | USE EXCESS COLD PROCESS FLUID FOR INDUSTRIAL COOLING NEEDS | $313,428 | $142,400 | Not Implemented |
MI0316 # 02 Y:2017 | 02 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $72,034 | $39,216 | Implemented |