Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,715
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0952 # 06 Y:2016 | 06 | 2016 | INSTALL TURBULATORS | $6,373 | $3,750 | Not Implemented |
UD0952 # 07 Y:2016 | 07 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,764 | $1,000 | Implemented |
UD0952 # 08 Y:2016 | 08 | 2016 | UPGRADE CONTROLS ON COMPRESSORS | $1,652 | $800 | Implemented |
UD0952 # 09 Y:2016 | 09 | 2016 | INSTALL OCCUPANCY SENSORS | $10,838 | $19,760 | Not Implemented |
UD0952 # 10 Y:2016 | 10 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,795 | $12,240 | Implemented |
UD0952 # 11 Y:2016 | 11 | 2016 | DISCONNECT BALLASTS | $546 | $80 | Not Implemented |
UD0952 # 12 Y:2016 | 12 | 2016 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $9,559 | $23,200 | Not Implemented |
UD0952 # 13 Y:2016 | 13 | 2016 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $17,619 | $90,000 | Not Implemented |
SD0533 # 04 Y:2016 | 04 | 2016 | OPTIMIZE PLANT POWER FACTOR | $4,856 | $2,339 | Not Implemented |
SD0533 # 05 Y:2016 | 05 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,056 | $1,000 | Implemented |
SD0533 # 06 Y:2016 | 06 | 2016 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $2,827 | $5,600 | Not Implemented |
SD0533 # 07 Y:2016 | 07 | 2016 | USE PHOTOCELL CONTROLS | $2,169 | $3,700 | Implemented |
OK0947 # 01 Y:2016 | 01 | 2016 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $11,871 | $92,000 | Not Implemented |
OK0947 # 02 Y:2016 | 02 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $985 | $3,780 | Not Implemented |
OK0947 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,495 | $9,720 | Not Implemented |
OK0947 # 04 Y:2016 | 04 | 2016 | INSULATE BARE EQUIPMENT | $11,683 | $10,036 | Not Implemented |
OK0947 # 05 Y:2016 | 05 | 2016 | USE RADIANT HEATER FOR SPOT HEATING | $3,754 | $19,570 | Not Implemented |
OK0947 # 06 Y:2016 | 06 | 2016 | INSTALL SET-BACK TIMERS | $483 | $410 | Not Implemented |
OK0947 # 07 Y:2016 | 07 | 2016 | OPTIMIZE PLANT POWER FACTOR | $4,680 | $27,500 | Not Implemented |
OK0947 # 08 Y:2016 | 08 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $368 | $822 | Not Implemented |
OK0947 # 09 Y:2016 | 09 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,092 | $2,000 | Not Implemented |
OK0947 # 10 Y:2016 | 10 | 2016 | TURN OFF EQUIPMENT WHEN NOT IN USE | $362 | $540 | Not Implemented |
SD0533 # 01 Y:2016 | 01 | 2016 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $65,643 | $292,000 | Not Implemented |
SD0533 # 02 Y:2016 | 02 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,187 | $25,315 | Implemented |
SD0533 # 03 Y:2016 | 03 | 2016 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $11,672 | $7,800 | Implemented |