IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,715

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0952 # 06 Y:2016 06 2016 INSTALL TURBULATORS $6,373 $3,750 Not Implemented
UD0952 # 07 Y:2016 07 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,764 $1,000 Implemented
UD0952 # 08 Y:2016 08 2016 UPGRADE CONTROLS ON COMPRESSORS $1,652 $800 Implemented
UD0952 # 09 Y:2016 09 2016 INSTALL OCCUPANCY SENSORS $10,838 $19,760 Not Implemented
UD0952 # 10 Y:2016 10 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,795 $12,240 Implemented
UD0952 # 11 Y:2016 11 2016 DISCONNECT BALLASTS $546 $80 Not Implemented
UD0952 # 12 Y:2016 12 2016 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $9,559 $23,200 Not Implemented
UD0952 # 13 Y:2016 13 2016 USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME $17,619 $90,000 Not Implemented
SD0533 # 04 Y:2016 04 2016 OPTIMIZE PLANT POWER FACTOR $4,856 $2,339 Not Implemented
SD0533 # 05 Y:2016 05 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,056 $1,000 Implemented
SD0533 # 06 Y:2016 06 2016 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $2,827 $5,600 Not Implemented
SD0533 # 07 Y:2016 07 2016 USE PHOTOCELL CONTROLS $2,169 $3,700 Implemented
OK0947 # 01 Y:2016 01 2016 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $11,871 $92,000 Not Implemented
OK0947 # 02 Y:2016 02 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $985 $3,780 Not Implemented
OK0947 # 03 Y:2016 03 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,495 $9,720 Not Implemented
OK0947 # 04 Y:2016 04 2016 INSULATE BARE EQUIPMENT $11,683 $10,036 Not Implemented
OK0947 # 05 Y:2016 05 2016 USE RADIANT HEATER FOR SPOT HEATING $3,754 $19,570 Not Implemented
OK0947 # 06 Y:2016 06 2016 INSTALL SET-BACK TIMERS $483 $410 Not Implemented
OK0947 # 07 Y:2016 07 2016 OPTIMIZE PLANT POWER FACTOR $4,680 $27,500 Not Implemented
OK0947 # 08 Y:2016 08 2016 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $368 $822 Not Implemented
OK0947 # 09 Y:2016 09 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,092 $2,000 Not Implemented
OK0947 # 10 Y:2016 10 2016 TURN OFF EQUIPMENT WHEN NOT IN USE $362 $540 Not Implemented
SD0533 # 01 Y:2016 01 2016 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $65,643 $292,000 Not Implemented
SD0533 # 02 Y:2016 02 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $17,187 $25,315 Implemented
SD0533 # 03 Y:2016 03 2016 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $11,672 $7,800 Implemented