Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
146,354
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0217 # 01 Y:1984 | 01 | 1984 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $51,259 | $42,740 | Not Implemented |
TN0217 # 02 Y:1984 | 02 | 1984 | INSTALL / REPAIR INSULATION ON STEAM LINES | $24,926 | $1,300 | Implemented |
TN0217 # 03 Y:1984 | 03 | 1984 | REPAIR AND ELIMINATE STEAM LEAKS | $22,604 | $1,425 | Implemented |
TN0217 # 04 Y:1984 | 04 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $12,424 | $1,200 | Implemented |
TN0217 # 05 Y:1984 | 05 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $10,488 | $0 | Not Implemented |
TN0217 # 06 Y:1984 | 06 | 1984 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,447 | $0 | Implemented |
TN0217 # 07 Y:1984 | 07 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,610 | $50 | Implemented |
TN0218 # 01 Y:1984 | 01 | 1984 | USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM | $8,908 | $15,000 | Not Implemented |
TN0218 # 02 Y:1984 | 02 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,382 | $0 | Not Implemented |
TN0218 # 03 Y:1984 | 03 | 1984 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $4,352 | $3,700 | Implemented |
TN0218 # 04 Y:1984 | 04 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,746 | $180 | Not Implemented |
TN0218 # 05 Y:1984 | 05 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $5,078 | $4,350 | Not Implemented |
TN0218 # 06 Y:1984 | 06 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $758 | $0 | Not Implemented |
TN0218 # 07 Y:1984 | 07 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $677 | $90 | Implemented |
TN0212 # 01 Y:1984 | 01 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $9,487 | $400 | Implemented |
UD0132 # 01 Y:1984 | 01 | 1984 | INSTALL / REPAIR INSULATION ON STEAM LINES | $6,520 | $4,200 | Not Implemented |
UD0132 # 02 Y:1984 | 02 | 1984 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,478 | $500 | Implemented |
UD0132 # 03 Y:1984 | 03 | 1984 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $698 | $1,436 | Implemented |
UD0132 # 04 Y:1984 | 04 | 1984 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $823 | $0 | Implemented |
UD0132 # 05 Y:1984 | 05 | 1984 | INSTALL / REPAIR INSULATION ON STEAM LINES | $130 | $100 | Not Implemented |
UD0133 # 01 Y:1984 | 01 | 1984 | USE OPTIMUM THICKNESS INSULATION | $5,281 | $5,000 | Not Implemented |
UD0133 # 02 Y:1984 | 02 | 1984 | USE OPTIMUM THICKNESS INSULATION | $19,560 | $40,500 | Not Implemented |
UD0133 # 03 Y:1984 | 03 | 1984 | INSTALL SET-BACK TIMERS | $1,754 | $1,271 | Implemented |
UD0133 # 04 Y:1984 | 04 | 1984 | REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE | $3,629 | $6,000 | Implemented |
UD0133 # 05 Y:1984 | 05 | 1984 | SUBSTITUTE HOT PROCESS FLUIDS FOR STEAM | $1,721 | $3,000 | Not Implemented |