IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

158,308

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LT0128 # 01 Y:1988 01 1988 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,210 $600 Implemented
LT0128 # 02 Y:1988 02 1988 INSTALL / REPAIR INSULATION ON STEAM LINES $5,334 $2,500 Implemented
LT0128 # 03 Y:1988 03 1988 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $476 $350 Implemented
LT0128 # 04 Y:1988 04 1988 INSULATE BARE EQUIPMENT $5,670 $11,000 Not Implemented
LT0128 # 05 Y:1988 05 1988 REPAIR AND ELIMINATE STEAM LEAKS $315 $550 Implemented
LT0128 # 06 Y:1988 06 1988 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $339 $600 Implemented
LT0128 # 07 Y:1988 07 1988 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $68 $180 Not Implemented
LT0128 # 08 Y:1988 08 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $176 $0 Implemented
LT0128 # 09 Y:1988 09 1988 INSTALL TIMERS AND/OR THERMOSTATS $177 $150 Implemented
LT0128 # 10 Y:1988 10 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $195 $49 Implemented
LT0129 # 01 Y:1988 01 1988 INSULATE BARE EQUIPMENT $6,480 $5,500 Implemented
LT0129 # 02 Y:1988 02 1988 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $500 $0 Not Implemented
LT0129 # 03 Y:1988 03 1988 RECOVER WASTE HEAT FROM EQUIPMENT $3,300 $7,900 Not Implemented
LT0129 # 04 Y:1988 04 1988 USE RADIANT HEATER FOR SPOT HEATING $9,900 $5,000 Not Implemented
LT0129 # 05 Y:1988 05 1988 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,520 $5,557 Implemented
LT0129 # 06 Y:1988 06 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $7,020 $0 Implemented
LT0129 # 07 Y:1988 07 1988 AIR CONDITION ONLY SPACE NECESSARY $6,100 $6,000 Not Implemented
LT0129 # 08 Y:1988 08 1988 INSTALL TIMERS AND/OR THERMOSTATS $590 $600 Not Implemented
LT0129 # 09 Y:1988 09 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $53 $55 Implemented
MA0123 # 01 Y:1988 01 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $366 $139 Implemented
MA0123 # 02 Y:1988 02 1988 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $3,548 $21,500 Implemented
MA0123 # 03 Y:1988 03 1988 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $352 $300 Not Implemented
MA0123 # 04 Y:1988 04 1988 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $963 $4,800 Not Implemented
MA0123 # 05 Y:1988 05 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,090 $0 Implemented
MA0123 # 06 Y:1988 06 1988 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,768 $229 Implemented