Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,394

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AS0389 # 03 Y:2004 03 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $310 $506 Not Implemented
AS0389 # 04 Y:2004 04 2004 USE GRAVITY FEEDS WHEREVER POSSIBLE $345 $150 Not Implemented
AS0389 # 05 Y:2004 05 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,971 $7,343 Implemented
MI0093 # 01 Y:2004 01 2004 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $2,620 $0 Not Implemented
MI0093 # 02 Y:2004 02 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $44,199 $0 Not Implemented
MI0093 # 03 Y:2004 03 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $553 $0 Not Implemented
MI0093 # 04 Y:2004 04 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,800 $0 Not Implemented
MI0093 # 05 Y:2004 05 2004 INCREASE USE OF AUTOMATION $28,521 $0 Not Implemented
MI0093 # 06 Y:2004 06 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,994 $0 Not Implemented
MI0093 # 07 Y:2004 07 2004 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $8,755 $510 Implemented
MI0093 # 08 Y:2004 08 2004 INSTALL ROTATING CAROUSELS TO REDUCE SET-UP TIMES $23,333 $21,000 Implemented
MI0093 # 09 Y:2004 09 2004 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $12,561 $0 Not Implemented
MS0259 # 01 Y:2004 01 2004 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER $111,932 $0 Not Implemented
MS0259 # 02 Y:2004 02 2004 REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE $48,984 $0 Not Implemented
MS0259 # 03 Y:2004 03 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $15,687 $150 Implemented
MS0259 # 04 Y:2004 04 2004 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $12,622 $0 Not Implemented
MS0259 # 05 Y:2004 05 2004 HEAT WATER DURING OFF-PEAK PERIODS AND STORE FOR LATER USE $6,267 $18,138 Not Implemented
MS0259 # 06 Y:2004 06 2004 HEAT WATER WITH EXHAUST HEAT $5,972 $0 Implemented
MS0259 # 07 Y:2004 07 2004 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $5,481 $245,000 Implemented
MS0259 # 08 Y:2004 08 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,277 $0 Implemented
MS0259 # 09 Y:2004 09 2004 INSTALL TIMERS AND/OR THERMOSTATS $2,598 $0 Not Implemented
MS0259 # 10 Y:2004 10 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,655 $0 Not Implemented
MA0560 # 01 Y:2004 01 2004 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $42,752 $238,150 Implemented
MA0560 # 02 Y:2004 02 2004 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $32,756 $23,710 Implemented
MA0560 # 03 Y:2004 03 2004 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $5,875 $1,200 Implemented