IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,553

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0054 # 04 Y:1986 04 1986 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $811 $0 Implemented
MA0051 # 01 Y:1986 01 1986 INSTALL SET-BACK TIMERS $377 $75 Implemented
MA0051 # 02 Y:1986 02 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,235 $248 Implemented
MA0051 # 03 Y:1986 03 1986 REPAIR OR REPLACE STEAM TRAPS $14,400 $650 Implemented
MA0051 # 04 Y:1986 04 1986 COVER OPEN TANKS $12,580 $1,239 Not Implemented
MA0051 # 05 Y:1986 05 1986 INSTALL EFFICIENT RECTIFIERS $8,784 $40,000 Implemented
MA0049 # 01 Y:1985 01 1985 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $721 $500 Implemented
MA0049 # 02 Y:1985 02 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,081 $87 Not Implemented
MA0049 # 03 Y:1985 03 1985 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $15,656 $40,000 Not Implemented
MA0049 # 04 Y:1985 04 1985 TURN OFF EQUIPMENT WHEN NOT IN USE $33,063 $3,200 Not Implemented
MA0050 # 01 Y:1985 01 1985 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $16,247 $16,000 Not Implemented
MA0050 # 02 Y:1985 02 1985 INSTALL STORM WINDOWS AND DOORS $1,558 $1,600 Implemented
MA0050 # 03 Y:1985 03 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,600 $55 Implemented
ST0041 # 01 Y:1985 01 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,854 $7,389 Implemented
ST0041 # 02 Y:1985 02 1985 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $917 $104 Implemented
ST0041 # 03 Y:1985 03 1985 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $343 $0 Implemented
ST0041 # 04 Y:1985 04 1985 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $478 $870 Not Implemented
ST0041 # 05 Y:1985 05 1985 INSTALL / REPAIR INSULATION ON STEAM LINES $1,556 $1,020 Not Implemented
ST0041 # 06 Y:1985 06 1985 RECOVER WASTE HEAT FROM EQUIPMENT $391 $900 Not Implemented
ST0041 # 07 Y:1985 07 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,510 $537 Implemented
ST0041 # 08 Y:1985 08 1985 REPLACE BROKEN WINDOWS AND/OR WINDOW SASH $3,038 $935 Not Implemented
ST0041 # 09 Y:1985 09 1985 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,227 $2,200 Not Implemented
MA0038 # 01 Y:1985 01 1985 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,045 $300 Implemented
MA0038 # 02 Y:1985 02 1985 RECOVER WASTE HEAT FROM EQUIPMENT $3,400 $2,938 Implemented
MA0038 # 03 Y:1985 03 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $892 $112 Implemented