Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,872
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AR0146 # 01 Y:1998 | 01 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $6,771 | $840 | Implemented |
AR0146 # 02 Y:1998 | 02 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $16,850 | $300 | Implemented |
AR0146 # 03 Y:1998 | 03 | 1998 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $29,234 | $18,900 | Implemented |
AR0146 # 04 Y:1998 | 04 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,398 | $1,340 | Implemented |
AR0146 # 05 Y:1998 | 05 | 1998 | REDUCE OR ELIMINATE WASTE | $224,855 | $8,100 | Implemented |
AR0146 # 06 Y:1998 | 06 | 1998 | REPROCESS SPENT OILS ON SITE FOR RE-USE | $17,264 | $0 | Not Implemented |
AR0146 # 07 Y:1998 | 07 | 1998 | $3,780 | $0 | Implemented | |
AR0146 # 08 Y:1998 | 08 | 1998 | $98,162 | $386,400 | Implemented | |
DS0123 # 01 Y:1998 | 01 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $7,965 | $4,320 | Implemented |
DS0123 # 02 Y:1998 | 02 | 1998 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $580 | $160 | Not Implemented |
DS0123 # 03 Y:1998 | 03 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,304 | $4,750 | Not Implemented |
DS0123 # 04 Y:1998 | 04 | 1998 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $13,292 | $400 | Not Implemented |
DS0123 # 05 Y:1998 | 05 | 1998 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $564 | $0 | Implemented |
GT0640 # 01 Y:1998 | 01 | 1998 | OPTIMIZE PLANT POWER FACTOR | $28,530 | $45,720 | Implemented |
GT0640 # 02 Y:1998 | 02 | 1998 | COMBINE UTILITY METERS | $5,560 | $0 | Implemented |
GT0640 # 03 Y:1998 | 03 | 1998 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $9,249 | $0 | Not Implemented |
GT0640 # 04 Y:1998 | 04 | 1998 | UPGRADE CONTROLS ON COMPRESSORS | $7,000 | $5,000 | Implemented |
GT0640 # 05 Y:1998 | 05 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,590 | $200 | Not Implemented |
GT0640 # 06 Y:1998 | 06 | 1998 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,660 | $5,675 | Implemented |
GT0640 # 07 Y:1998 | 07 | 1998 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $7,741 | $7,900 | Implemented |
GT0640 # 08 Y:1998 | 08 | 1998 | METER WASTE WATER | $7,180 | $8,000 | Implemented |
GT0640 # 09 Y:1998 | 09 | 1998 | REPLACE THE CHLORINATION STAGE WITH AN OXYGEN OR OZONE STAGE | $36,424 | $92,125 | Not Implemented |
WI0332 # 01 Y:1998 | 01 | 1998 | $72,000 | $150,000 | Implemented | |
WI0332 # 02 Y:1998 | 02 | 1998 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $16,089 | $500 | Implemented |
WI0332 # 03 Y:1998 | 03 | 1998 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $5,188 | $14,000 | Not Implemented |