Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,616
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0056 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,865 | $38,883 | Implemented |
UA0056 # 02 Y:2010 | 02 | 2010 | USE PHOTOCELL CONTROLS | $451 | $900 | Implemented |
UA0056 # 03 Y:2010 | 03 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,084 | $640 | Not Implemented |
UA0056 # 04 Y:2010 | 04 | 2010 | INSTALL TIMERS AND/OR THERMOSTATS | $5,615 | $2,000 | Implemented |
UA0056 # 05 Y:2010 | 05 | 2010 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $6,045 | $240 | Implemented |
UA0055 # 01 Y:2010 | 01 | 2010 | USE OPTIMUM TEMPERATURE | $30,674 | $1,072 | Implemented |
UA0055 # 02 Y:2010 | 02 | 2010 | USE OPTIMUM THICKNESS INSULATION | $12,398 | $1,602 | Not Implemented |
UA0055 # 03 Y:2010 | 03 | 2010 | USE MINIMUM SAFE OVEN VENTILATION | $4,422 | $990 | Not Implemented |
UA0055 # 04 Y:2010 | 04 | 2010 | INSULATE BARE EQUIPMENT | $14,550 | $5,020 | Not Implemented |
UA0055 # 05 Y:2010 | 05 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $3,444 | $1,970 | Not Implemented |
UA0055 # 06 Y:2010 | 06 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,545 | $640 | Not Implemented |
UA0055 # 07 Y:2010 | 07 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,014 | $1,500 | Implemented |
UA0055 # 08 Y:2010 | 08 | 2010 | USE PHOTOCELL CONTROLS | $983 | $354 | Not Implemented |
UA0055 # 09 Y:2010 | 09 | 2010 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $341 | $106 | Not Implemented |
UA0055 # 10 Y:2010 | 10 | 2010 | INSTALL OCCUPANCY SENSORS | $559 | $387 | Not Implemented |
UA0055 # 11 Y:2010 | 11 | 2010 | DISCONNECT BALLASTS | $123 | $80 | Implemented |
UA0055 # 12 Y:2010 | 12 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $114 | $250 | Not Implemented |
UA0054 # 01 Y:2010 | 01 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $31,442 | $1,000 | Not Implemented |
UA0054 # 02 Y:2010 | 02 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,010 | $7,000 | Implemented |
UA0054 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $86,265 | $71,625 | Not Implemented |
UA0054 # 04 Y:2010 | 04 | 2010 | USE PHOTOCELL CONTROLS | $2,443 | $1,893 | Not Implemented |
UA0054 # 05 Y:2010 | 05 | 2010 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $42,638 | $40,400 | Not Implemented |
UA0054 # 06 Y:2010 | 06 | 2010 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $25,338 | $6,850 | Not Implemented |
UA0054 # 07 Y:2010 | 07 | 2010 | INSTALL TIMERS AND/OR THERMOSTATS | $4,372 | $3,230 | Implemented |
UA0053 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,526 | $53,770 | Not Implemented |