Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,872
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0202 # 06 Y:1998 | 06 | 1998 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $410 | $566 | Not Implemented |
IA0202 # 07 Y:1998 | 07 | 1998 | MINIMIZE WATER USAGE | $19,371 | $25,051 | Not Implemented |
IA0202 # 08 Y:1998 | 08 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $10,280 | $7,990 | Implemented |
IA0202 # 09 Y:1998 | 09 | 1998 | INSTALL AUTOMATIC PACKING EQUIPMENT | $1,151,761 | $500,000 | Not Implemented |
IA0202 # 10 Y:1998 | 10 | 1998 | INSTALL AUTOMATIC PACKING EQUIPMENT | $215,761 | $500,000 | Not Implemented |
IA0202 # 11 Y:1998 | 11 | 1998 | INSTALL AUTOMATIC PACKING EQUIPMENT | $31,068 | $7,800 | Implemented |
IA0202 # 12 Y:1998 | 12 | 1998 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $28,526 | $2,950 | Implemented |
IA0202 # 13 Y:1998 | 13 | 1998 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $1,179 | $3,763 | Implemented |
WV0145 # 01 Y:1998 | 01 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,801 | $1,250 | Implemented |
WV0145 # 02 Y:1998 | 02 | 1998 | INSULATE BARE EQUIPMENT | $4,143 | $734 | Implemented |
WV0145 # 03 Y:1998 | 03 | 1998 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $2,936 | $1,000 | Implemented |
WV0145 # 04 Y:1998 | 04 | 1998 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $595 | $1,440 | Not Implemented |
WV0145 # 05 Y:1998 | 05 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,410 | $340 | Not Implemented |
WV0145 # 06 Y:1998 | 06 | 1998 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,068 | $3,700 | Not Implemented |
WV0145 # 07 Y:1998 | 07 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $516 | $0 | Not Implemented |
WV0145 # 08 Y:1998 | 08 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,635 | $7,710 | Not Implemented |
WV0145 # 09 Y:1998 | 09 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,762 | $11,820 | Implemented |
WV0145 # 10 Y:1998 | 10 | 1998 | DISCONNECT BALLASTS | $3,120 | $1,530 | Implemented |
WV0145 # 11 Y:1998 | 11 | 1998 | USE SYNTHETIC LUBRICANT | $1,076 | $500 | Implemented |
WV0145 # 12 Y:1998 | 12 | 1998 | BURN A LESS EXPENSIVE GRADE OF FUEL | $13,250 | $12,000 | Not Implemented |
WV0145 # 13 Y:1998 | 13 | 1998 | USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT | $543,058 | $2,440,200 | Not Implemented |
WV0145 # 14 Y:1998 | 14 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,349 | $1,365 | Not Implemented |
WV0145 # 15 Y:1998 | 15 | 1998 | INSULATE BARE EQUIPMENT | $2,343 | $833 | Implemented |
WV0145 # 16 Y:1998 | 16 | 1998 | INSULATE BARE EQUIPMENT | $527 | $160 | Implemented |
WV0145 # 17 Y:1998 | 17 | 1998 | LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE | $1,559 | $570 | Not Implemented |