IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,520

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OD0145 # 01 Y:1999 01 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,482 $38,557 Not Implemented
OD0145 # 02 Y:1999 02 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $275 $20 Not Implemented
OD0145 # 03 Y:1999 03 1999 TURN OFF EQUIPMENT WHEN NOT IN USE $1,280 $495 Implemented
OD0145 # 04 Y:1999 04 1999 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,396 $220 Implemented
OD0144 # 01 Y:1999 01 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,762 $39,160 Not Implemented
OD0144 # 02 Y:1999 02 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,069 $900 Not Implemented
OD0144 # 03 Y:1999 03 1999 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $420 $490 Not Implemented
OD0144 # 04 Y:1999 04 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,332 $20 Not Implemented
OD0144 # 05 Y:1999 05 1999 UPGRADE CONTROLS ON COMPRESSORS $4,446 $140 Not Implemented
AM0355 # 01 Y:1999 01 1999 MODIFY STARTUP/SHUTDOWN TIMES $25,130 $0 Implemented
AM0355 # 02 Y:1999 02 1999 REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT $5,910 $150 Not Implemented
AM0355 # 03 Y:1999 03 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,285 $1,400 Implemented
AM0355 # 04 Y:1999 04 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,300 $500 Implemented
AM0355 # 05 Y:1999 05 1999 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $570 $150 Implemented
AM0355 # 06 Y:1999 06 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $540 $600 Not Implemented
AM0355 # 07 Y:1999 07 1999 USE SYNTHETIC LUBRICANT $470 $0 Not Implemented
AM0355 # 08 Y:1999 08 1999 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $360 $1,480 Not Implemented
AM0355 # 09 Y:1999 09 1999 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $120 $0 Implemented
UD0580 # 01 Y:1999 01 1999 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT $862,392 $1,300,000 Not Implemented
UD0580 # 02 Y:1999 02 1999 ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS $134,400 $400,000 Not Implemented
UD0580 # 03 Y:1999 03 1999 RECOVER AND REUSE COOLING WATER $52,000 $140,000 Not Implemented
UD0580 # 04 Y:1999 04 1999 MOVE PRODUCT USING MECHANICAL MEANS $39,393 $10,000 Not Implemented
UD0580 # 05 Y:1999 05 1999 USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER $27,840 $3,500 Implemented
UD0580 # 06 Y:1999 06 1999 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $27,804 $11,744 Implemented
UD0580 # 07 Y:1999 07 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $19,051 $30,337 Implemented