Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,597
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0195 # 04 Y:2017 | 04 | 2017 | USE MINIMUM STEAM OPERATING PRESSURE | $457 | $0 | Not Implemented |
IC0195 # 05 Y:2017 | 05 | 2017 | INSTALL / REPAIR INSULATION ON STEAM LINES | $49 | $6 | Not Implemented |
IC0195 # 06 Y:2017 | 06 | 2017 | REPLACE BOILER | $183,000 | $30,000 | Implemented |
IC0195 # 07 Y:2017 | 07 | 2017 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $32,126 | $16,175 | Not Implemented |
IC0195 # 08 Y:2017 | 08 | 2017 | UPGRADE CONTROLS ON COMPRESSORS | $3,210 | $2,555 | Not Implemented |
IC0195 # 09 Y:2017 | 09 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,417 | $5,650 | Implemented |
IC0195 # 10 Y:2017 | 10 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,782 | $11,163 | Implemented |
IC0195 # 11 Y:2017 | 11 | 2017 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $697,569 | $2,619,820 | Not Implemented |
SU0446 # 01 Y:2017 | 01 | 2017 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,759 | $0 | Implemented |
SU0446 # 02 Y:2017 | 02 | 2017 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $10,711 | $7,161 | Not Implemented |
SU0446 # 03 Y:2017 | 03 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $304 | $234 | Not Implemented |
SU0446 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $170 | $165 | Implemented |
SU0446 # 05 Y:2017 | 05 | 2017 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $6,295 | $18,204 | Not Implemented |
SU0446 # 06 Y:2017 | 06 | 2017 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $290 | $854 | Not Implemented |
LE0440 # 01 Y:2017 | 01 | 2017 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $14,163 | $17 | Implemented |
LE0440 # 02 Y:2017 | 02 | 2017 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $97,167 | $5,000 | Implemented |
LE0440 # 03 Y:2017 | 03 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $21,749 | $3,000 | Implemented |
LE0440 # 04 Y:2017 | 04 | 2017 | RECOVER WASTE HEAT FROM EQUIPMENT | $41,418 | $13,000 | Implemented |
LE0440 # 05 Y:2017 | 05 | 2017 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $55,847 | $28,000 | Not Implemented |
LE0440 # 06 Y:2017 | 06 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $128,735 | $65,000 | Not Implemented |
LE0440 # 07 Y:2017 | 07 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $40,410 | $26,250 | Not Implemented |
LE0440 # 08 Y:2017 | 08 | 2017 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $86,307 | $68,000 | Implemented |
LE0440 # 09 Y:2017 | 09 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $22,392 | $38,954 | Implemented |
LE0440 # 10 Y:2017 | 10 | 2017 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $14,063 | $56,424 | Implemented |
LE0440 # 11 Y:2017 | 11 | 2017 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $4,060 | $20,000 | Implemented |