Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,777
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0022 # 04 Y:1992 | 04 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $774 | $134 | Implemented |
IA0022 # 05 Y:1992 | 05 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,737 | $1,196 | Implemented |
IA0022 # 06 Y:1992 | 06 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $538 | $229 | Implemented |
IA0022 # 07 Y:1992 | 07 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,988 | $100 | Not Implemented |
IA0023 # 01 Y:1992 | 01 | 1992 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $136,664 | $13,000 | n/a |
IA0023 # 02 Y:1992 | 02 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,994 | $16 | n/a |
IA0023 # 03 Y:1992 | 03 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,957 | $1,480 | n/a |
IA0023 # 04 Y:1992 | 04 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,986 | $8,825 | n/a |
IA0023 # 05 Y:1992 | 05 | 1992 | INSTALL SET-BACK TIMERS | $1,114 | $1,188 | n/a |
IA0023 # 06 Y:1992 | 06 | 1992 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,709 | $8,000 | n/a |
IA0023 # 07 Y:1992 | 07 | 1992 | OPTIMIZE PLANT POWER FACTOR | $94,150 | $84,875 | n/a |
IA0023 # 08 Y:1992 | 08 | 1992 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $211,326 | $1 | n/a |
IA0024 # 01 Y:1992 | 01 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $12,552 | $51,000 | Implemented |
IA0024 # 02 Y:1992 | 02 | 1992 | INSTALL TIMERS AND/OR THERMOSTATS | $8,634 | $3,600 | Not Implemented |
IA0024 # 03 Y:1992 | 03 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,997 | $467 | Not Implemented |
IA0024 # 04 Y:1992 | 04 | 1992 | INSTALL SET-BACK TIMERS | $857 | $1,660 | Not Implemented |
IA0024 # 05 Y:1992 | 05 | 1992 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $422 | $450 | Not Implemented |
IA0024 # 06 Y:1992 | 06 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,454 | $50 | Implemented |
IA0024 # 07 Y:1992 | 07 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,218 | $1,218 | Implemented |
IA0024 # 08 Y:1992 | 08 | 1992 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $4,688 | $426 | Implemented |
IA0024 # 09 Y:1992 | 09 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,941 | $100 | Not Implemented |
IA0025 # 01 Y:1992 | 01 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,172 | $50 | Not Implemented |
IA0025 # 02 Y:1992 | 02 | 1992 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,350 | $30 | Implemented |
IA0025 # 03 Y:1992 | 03 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,129 | $200 | Not Implemented |
IA0025 # 04 Y:1992 | 04 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,132 | $126 | Not Implemented |