IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,417

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0405 # 02 Y:1990 02 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $31,990 $74,360 Not Implemented
GT0405 # 03 Y:1990 03 1990 INSTALL SET-BACK TIMERS $570 $400 Implemented
GT0405 # 04 Y:1990 04 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $27,873 $4,000 Implemented
GT0405 # 05 Y:1990 05 1990 REDUCE FLUID FLOW RATES $38,794 $13,600 Not Implemented
GT0405 # 06 Y:1990 06 1990 INCREASE AMOUNT OF CONDENSATE RETURNED $36,022 $10,000 Implemented
GT0405 # 07 Y:1990 07 1990 MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE $5,990 $4,600 Not Implemented
MA0177 # 01 Y:1990 01 1990 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $5,107 $14,700 Not Implemented
MA0177 # 02 Y:1990 02 1990 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $10,876 $21,853 Not Implemented
MA0177 # 03 Y:1990 03 1990 INSTALL TIMERS AND/OR THERMOSTATS $822 $120 Implemented
MA0177 # 04 Y:1990 04 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,411 $8,500 Implemented
OK0308 # 01 Y:1990 01 1990 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,691 $160 Implemented
OK0308 # 02 Y:1990 02 1990 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $157 $228 Implemented
OK0308 # 03 Y:1990 03 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $407 $132 Implemented
OK0308 # 04 Y:1990 04 1990 INSTALL TURBULATORS $214 $260 Implemented
OK0308 # 05 Y:1990 05 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,258 $2,275 Implemented
OK0308 # 06 Y:1990 06 1990 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS $52,043 $42,000 Not Implemented
OK0308 # 07 Y:1990 07 1990 USE COLD WASTE WATER TO COOL CHILLER FEED WATER $8,121 $14,000 Not Implemented
MA0174 # 01 Y:1990 01 1990 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $388 $649 Not Implemented
MA0174 # 02 Y:1990 02 1990 DIRECT WARMEST AIR TO COMBUSTION INTAKE $992 $865 Not Implemented
MA0174 # 03 Y:1990 03 1990 OPTIMIZE PLANT POWER FACTOR $62,064 $80,000 Implemented
MA0174 # 04 Y:1990 04 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $6,525 $120 Implemented
MA0174 # 05 Y:1990 05 1990 INSTALL SET-BACK TIMERS $6,525 $1,524 Implemented
MA0174 # 06 Y:1990 06 1990 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $24,108 $27,827 Not Implemented
MA0174 # 07 Y:1990 07 1990 RECOVER WASTE HEAT FROM EQUIPMENT $35,725 $19,518 Not Implemented
MA0175 # 01 Y:1990 01 1990 INSTALL SET-BACK TIMERS $293 $129 Not Implemented